Product Description
* Custom configurations & pricing available. Schedule a consultation to find the perfect system for your application!
Schedule a ConsultationThis System Includes:
- G1312 binary pump
- G1314 VWD detector
- G1322 degasser
- G1330 autosampler
- G1316 thermostatted column compartment
- Agilent 1200 Solvent Tray with 2 solvent bottles
- Computer Data System with NEW Data (Clarity for Windows 10) Analysis Software
- New 19″ Flat Panel Monitor
- All cables, keyboard, mouse, & complete performance documentation
Like the 1100 series the 1200 series model is a workhorse for the demanding needs of any QA/QC lab for the most advanced analytical and method development applications.
The heart of any HPLC system is the pump. The 1200 binary pump model G1312 is designed for routine method development and high throughput gradient applications for greatest flexibility with extreme precision for demanding flow requirements such as LC mass spectrometry. Accurate flow rates coupled with low pulsation = awesome
The G1315 DAD detector gives you Spectral information from 190 to 950 nm The dual-lamp design and the temperature control of the Agilent 1200 Series diode array detectors ensure outstanding sensitivity. Photodiode arrays with 1024 elements, programmable slit width (1, 2, 4, 8, 16 nm) and the selection of nine different flow cells enable optimization of resolution, linearity and sensitivity….it will NOT cramp your analytical capability.
The 1200 series autosampler typical repeatability and LACK of carryover is astronomically outstanding. Superior injection precision and lowest carryover makes your runs trustworthy day in day out. The 1200 autosamplers provide for precision levels of < 0.5 % RSD over an injection volume range from 0.01 μL to 2000 μL. The unique flow-through design, combined with the external needle wash and optional multiple wash solvents, virtually eliminates carryover, even for highly adsorptive compounds.
Specifications
| Agilent 1200 G1311 Series Binary Pump | Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve |
| Setable flow range | 0.001 – 5 ml/min, in 0.001 ml/min increments |
| Flow precision | 0.07% RSD, or £ 0.02 min SD whatever is greater |
| Flow accuracy | ± 1% or 10 µl/min whatever is greater |
| Pressure | Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min |
| Gradient formation | Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure |
| Composition Range | 0 – 95 % or 5 – 100 %, user selectable |
| Agilent 1200 G1314 VWD Detector | 1 signal 13 Hz data rate |
| Wavelength range | 190 – 600 nm |
| Linear absorbance range | Greater than 2.5 AU (5 %) at 265 nm |
| Band width | 6.5 nm typical |
| Agilent G1316 TCC column compartment Temperature range | 10 degrees below ambient to 80 °C 10 degrees below ambient to 100 °C up to 80 °C: flow rates up to 5 ml/min up to 100 °C: flow rates up to 2.5 ml/min |
| Column capacity | Three 30 cm |
Agilent 1200 HPLC System Configurations
The modular Agilent 1200 HPLC system allows various configurations. Different combinations of modules, including pumps and detectors, can be tailored to specific applications and requirements. A typical configuration includes the pump, detector, autosampler, vacuum degasser, solvent module, Clarity software, computer system, HPIB cables, and manuals.
Modules include the Agilent 1200 Series Quaternary or Binary pump, and the 1200 Series Variable Wavelength Detector (VWD) or the Diode Array Detector (DAD). Both the VWD and DAD use a holmium oxide filter for automated wavelength verification and tracking the detector’s performance characteristics. The Agilent 1200 detectors also feature a new design that allows front access for the exchange of flow cells and pre-aligned lamps.
Agilent 1200 Configuration Options |
||||||
| Pump | Autosampler | Column Compartment | Detector | Degasser | Computer & Software | Installation & Training |
| G1310B Isocratic Pump | G1329B Standard Autosampler | G1316B Thermostatted Column Compartment for accurate temperature control | G1314B Variable Wavelength Detector (VWD) | G1322B Degasser | Computer w/ ChemStation | On-Site Installation & Familiarization |
| G1311B Quaternary Pump | G1367B High-Performance Autosampler | No Column Compartment | G1315B Diode Array Detector (DAD) | No Degasser | Computer w/ OpenLab | Remote Installation |
| G1312B Binary Pump | Fluorescence Detector G1321B | No Computer or Software | No Installation or Familiarization | |||
| G1362B Refractive Index Detector | ||||||
The available Agilent 1200 Series HPLC Systems offered by GMI include:
- Agilent 1200 Series Binary VWD System (Binary Pump, Variable Wavelength Detector)
- Agilent 1200 Series Binary DAD System (Binary Pump, Diode Array Detector)
- Agilent 1200 Series Quaternary MWD System (Quaternary Pump, Multiple Wavelength Detector)
- Agilent 1200 Series Quaternary DAD System (Quaternary Pump, Diode Array Detector)
* Custom configurations available. Schedule a consultation to find the perfect system for your application!
Schedule a Consultation user manual





Reviews