Product Description
- Full Spectral Range
- Well Volume Sensor
- Comprehensive Data Analysis Software
- Optical Validation
- Software Validation
Molecular Devices’ SpectraMax® Plus 384 Microplate Reader provides fast and reliable full spectral range detection for cuvettes, 96-well and 384-well microplates. This reader also makes use of a unique temperature-independent methodology for path length correction.
Running both standard spectrophotometer and microplate reader applications at the same time is possible with the SpectraMax® Plus 384. This benchmark for UV-visible microplate readers is capable of processing up to 384 samples in a single plate. A standard cuvette, 12 x 75 test tube as well as a 96- or 384-well microplate can be used in analyzing samples. Operators can also increase sample throughput by integrating this system into a full robotic mechanism that easily adjusts to fit sample handling requirements.
The SpectraMax Plus 384 reader is equipped with the innovative technology patented by Molecular Devices, the PathCheck® Sensor which measures the depth of samples in a microplate through optical path length. This technology allows for the automated regulation of well absorbance to a cuvette equivalent path length of 1 cm, which translates to 96 or 384 cuvettes.
The Data Acquisition & Analysis Software comes with each microplate reader. This premium all-in-one data software is capable of performing a wide range of ready-to-read protocols. Users will find pre-written µMax protocols that enable measurement of low volume applications. Using this software, the StakMax® Microplate Handling Stacker can also be flawlessly integrated with the SpectraMax Plus 384 system.
Specifications
| Dimensions (H x W x D) | 8.6 x 22.8 x 15 (in.) 22 x 58 x 38 (cm) |
| Weight | 30 lbs. (13.6 kg) |
| Power Consumption | |
| Power Source | 100-240 VAC, 4A 50/60 Hz |
| Robot Compatible | YES |
| Photometric Performance | |
| Wavelength Range | 190 – 1000 nm |
| Wavelength Selection | Monochromator, turnable in 1.0 nm increments |
| Wavelength Bandwidth | 2 nm |
| Wavelength Accuracy | ± 1.0 nm |
| Wavelength Repeatability | ± 0.2 nm |
| Photometric Range | 0 – 4.000 OD |
| Photometric Accuracy (microplate) | |
| Photometric Accuracy (cuvette) | |
| Photometric Precision | |
| PathCheck Sensor Management Error | |
| Baseline Flatness | |
| Stray Light | |
| Microplate read time (normal mode) | 96 wells in 9 seconds 384 wells in 29 seconds |
| Microplate read time (speed read mode) | 96 wells in 5 seconds 384 wells in 16 seconds |
| Temperature Regulation | |
| Temperature Range | Ambient +4°C to 45°C |
| Temperature Uniformity (microplate) | ± 0.5°C at 37°C |