Product Description
Jeio Tech IB4-S Incubators provide reliable and uniform temperature control for a wide range of biological and clinical applications. Designed with a forced convection system, the IB4 series ensures even temperature distribution throughout the chamber, making it ideal for microbial culture, sample incubation, and stability testing. Featuring a user-friendly digital PID controller, the IB4 allows precise temperature setting and monitoring, while its durable interior and adjustable shelves offer flexibility for various sample types. With quiet operation, enhanced insulation, and built-in safety features, the IB4 series delivers dependable performance for routine use in microbiology, biotechnology, and pharmaceutical laboratories.
Features
Intuitive Touch Controller
- Intuitive interface with 3.5-inch display.
- 'Wait on / Wait off' timer function.
Reliable Temperature Control Performance
- Temperature accuracy for wide range by 3-point calibration
- The upper and lower temperature limits can be set, enabling alerts for deviations to trigger quick actions.
- Uniform temperature distribution through airflow optimized for uniform heat transfer. (within ±0.41 °C at 37°C)
Convenient Experiment and Data Checking
- Support RS-232/USB port and software making easy operation and data management from PC. (option).
- Monitor and control anywhere, anytime with LC GreenBox. (Mobile Monitoring System, option)
- Monitor the temperature on BMS (Building Management System) for quick responses to abnormalities. (option)
- Integrated with 21 CFR Part 11 compliant LC DataKeeper, suitable for GMP audits. (option)
Enhanced Safety and Convenience
- Implemented with the highest-level overheating prevention system. (Patent 10-0397583)
- Over Temperature Limiter.
- Complaint to IEC Class II protection standards and temperature protection in line with DIN 12880 Class 3.1
- Logs the last 12 events, including run times, stops, and errors.
- Double stackable with stacking set (option) maximizes space utilization.
Multiple Features to Minimize Incubation Failure
- Using Water tray delays media drying, making incubation time longer. (option)
- Alarm is activated when door remains open longer than the set time to maintain internal temperature.
- Automatically resume the control of previous operations when restored within 30 seconds from blackouts.
- Controller can be locked with the button on the top, preventing any actions from unintended pressing.
Specifications
| Specification | Value |
|---|---|
| Chamber volume (L / cu ft) | 25 / 0.88 |
| Temperature | |
| Range (°C / °F) | Amb. +5 to 80 / Amb. +9 to 176 |
| Fluctuation at 37°C (±°C / °F) | 0.10 / 0.18 |
| Variation at 37°C (±°C / °F) | 0.23 / 0.41 |
| Heating time to 37°C (min) | 5 |
| Recovery time at 37°C (min) | 5 |
| Control panel | 3.5 inch TFT Color LCD |
| Communication interface | Optional USB-B, RS-232 |
| Recently event record | 12 ea |
| Interior (W x D x H, mm / inch) | 300 x 210 x 400 / 11.81 x 8.27 x 15.75 |
| Exterior (W x D x H, mm / inch) | 478 x 527 x 604 / 18.8 x 20.75 x 23.78 |
| Net weight (Kg / lbs) | 32 / 70.55 |
| Quantity of shelves (standard/max.) | 2 / 4 |
| Max. Load per shelf (Kg / lbs) | 20 / 44.09 |
| Electrical requirements | 120V, 60Hz, 5.8A |
| ※ Technical data according to DIN 12880 | |
Application
Incubators are used to maintain a stable temperature environment for the cultivation, storage, and testing of biological samples. Common applications include cell and microbial culture, enzyme reactions, sample incubation, and stability testing. They are widely used in microbiology, biotechnology, pharmaceutical, and clinical laboratories for growing bacteria, yeast, and other organisms under controlled conditions, as well as for warming reagents or samples prior to analysis.