Product Description
* Custom configurations available. Schedule a consultation to find the perfect system for your application!
Schedule a ConsultationThis System Includes:
- Agilent Model G1311 quaternary pump
- Agilent Model G1365D multiple wavelength detector
- Agilent Model G1322 degasser
- Agilent Model G1329 autosampler
- Agilent Model G1316 thermostatted column compartment
- Agilent 1200 Solvent Tray with 2 solvent bottles
- Computer Data System with NEW Data (Clarity for Windows 10) Analysis Software
- New 19″ Flat Panel Monitor
- All cables, keyboard, mouse, & complete performance documentation
Like the 1100 series the 1200 model is a workhorse for the demanding needs of any QA/QC lab for the most advanced analytical and method development applications.
The heart of any HPLC system is the pump. The 1200 quaternary pump model G1311 is designed for routine method development and high throughput gradient applications for greatest flexibility with multisolvent gradients by accessing up to 4 solvents. Accurate flow rates coupled with low pulsation = awesome
The G1314 VWD detector gives you high sensitivity information from 190 to 600 nm The dual-lamp design and the temperature control of the Agilent 1200 Series VWD ensure outstanding sensitivity….it will NOT cramp your analytical capability.
The 1200 series autosampler typical repeatability and LACK of carryover is astronomically outstanding. Superior injection precision and lowest carryover makes your runs trustworthy day in day out. The 1200 autosamplers provide for precision levels of < 0.5 % RSD over an injection volume range from 0.01 μL to 2000 μL. The unique flow-through design, combined with the external needle wash and optional multiple wash solvents, virtually eliminates carryover, even for highly adsorptive compounds.
Performance Specification Agilent 1200 G1311 Series Quaternary Pump
Type | Specification |
Hydraulic system | Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve |
Setable flow range | 0.001 – 10 ml/min, in 0.001 ml/min increments |
Flow range | 0.2 – 10.0 ml/min |
Flow precision | 0.07% RSD, or £ 0.02 min SD whatever is greater, based on retentiontime at constant room temperature |
Flow accuracy | ± 1% or 10 µl/min whatever is greater |
Pressure | Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min |
Pressure pulsation | less than 2 % amplitude (typically 1 MPa (10 bar) |
Compressibility compensation | User-selectable, based on mobile phase compressibility |
Recommended pH range | 1.0 – 12.5, solvents with pH less than 2.3 should not contain acids which attack stainless steel |
Gradient formation | Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 – 1100 µl, dependent on back pressure |
Composition Range | 0 – 95 % or 5 – 100 %, user selectable |
Composition Precision | < 0.2 % RSD, at 0.2 and 1 ml/min |
Recommended pH range | 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel |
Control and data evaluation | Agilent control software (e.g. Clarity, ChemStation, EZChrom, OL, etc.) |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready,start, stop and shut-down signals, LAN optional |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent Lab Monitor & Diagnostic Software), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
Housing | All materials recyclable |
Performance Specifications Agilent 1200 G1314 Variable Wavelength Detector
Type | Specification | |
Detection type | Double-beam photometer | |
Light source | Deuterium lamp | |
Wavelength range | 190–600 nm | |
Short term noise (ASTM) | ± 0.75 × 10-5 AU at 254 nm | |
Drift | 3 × 10-4 AU/hr at 254 nm | |
Linearity | > 2 AU (5%) upper limit | |
Wavelength accuracy | ± 1 nm | |
Band width | 6.5 nm typical | |
Flow cells | Standard: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High pressure: 14-µl volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum Micro: 1-µl volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum Semi-micro: 5-µl volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum |
|
Control and data evaluation | Agilent ChemStation for LC | |
Analog outputs | ||
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional | |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Lowvoltages in major maintenance areas. | |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. | |
Housing | All materials recyclable. |
Agilent 1200 HPLC System Configurations
The modular Agilent 1200 HPLC system allows various configurations. Different combinations of modules, including pumps and detectors, can be tailored to specific applications and requirements. A typical configuration includes the pump, detector, autosampler, vacuum degasser, solvent module, Clarity software, computer system, HPIB cables, and manuals.
Modules include the Agilent 1200 Series Quaternary or Binary pump, and the 1200 Series Variable Wavelength Detector (VWD) or the Diode Array Detector (DAD). Both the VWD and DAD use a holmium oxide filter for automated wavelength verification and tracking the detector’s performance characteristics. The Agilent 1200 detectors also feature a new design that allows front access for the exchange of flow cells and pre-aligned lamps.
Agilent 1200 Configuration Options |
||||||
Pump | Autosampler | Column Compartment | Detector | Degasser | Computer & Software | Installation & Training |
G1310B Isocratic Pump | G1329B Standard Autosampler | G1316B Thermostatted Column Compartment for accurate temperature control | G1314B Variable Wavelength Detector (VWD) | G1322B Degasser | Computer w/ ChemStation | On-Site Installation & Familiarization |
G1311B Quaternary Pump | G1367B High-Performance Autosampler | No Column Compartment | G1315B Diode Array Detector (DAD) | No Degasser | Computer w/ OpenLab | Remote Installation |
G1312B Binary Pump | Fluorescence Detector G1321B | No Computer or Software | No Installation or Familiarization | |||
G1362B Refractive Index Detector |
The available Agilent 1200 Series HPLC Systems offered by GMI include:
- Agilent 1200 Series Binary VWD System (Binary Pump, Variable Wavelength Detector)
- Agilent 1200 Series Binary DAD System (Binary Pump, Diode Array Detector)
- Agilent 1200 Series Quaternary MWD System (Quaternary Pump, Multiple Wavelength Detector)
- Agilent 1200 Series Quaternary DAD System (Quaternary Pump, Diode Array Detector)
* Custom configurations available. Schedule a consultation to find the perfect system for your application!
Schedule a Consultation user manual