Instrument Finder
-or-
For Sale Siemens/Bayer DCA 2000+ Analyzer - Inquire for Price (GMI has New and Used Instrumentation)
Hematology Analyzers arrow Siemens/Bayer DCA 2000+ Analyzer

Siemens/Bayer DCA 2000+ Analyzer


Siemens/Bayer DCA 2000+ Analyzer

Request Info or Pricing

Guaranteed 12 hour response time
We respect your privacy, we do not disclose to 3rd parties.
  • Totally self-contained reagent cartridges
  • Sample collection capillary holder
  • No costly, time-consuming calibration
  • Screen displays instructions, status, information and results
  • Up to 16 results stored in memory

Product Description

The Siemens/Bayer DCA 2000+ Analyzer is a point-of-care management platform for diabetes. This hematology analyzer efficiently performs hemoglobin A1c and microalbumin/creatinine tests in minutes. At the same time, the analyzer allows healthcare professionals to make immediate diabetes management adjustments. The DCA 2000+ Analyzer system also measures low concentrations of albumin, creatinine and albumin/creatinine ratio in urine. This method enables decentralized testing using random urine samples, resulting in early detection of problems associated with renal disease.

Because of its totally self-contained reagent cartridges, this Bayer DCA 2000+ glycohemoglobin analyzer requires no reagent preparation, mixing, or handling. The sample collection capillary holder is a central part of unique reagent cartridge. This factory-calibrated analyzer also eliminates all wet, costly, and time-consuming calibrations.

The Siemens DCA 2000+ Analyzer guarantees laboratory-accurate results in just minutes after testing, including results for HBA1c and microalbumin/creatinine ratio tests. Using random urine samples, the Siemens Bayer hematology analyzer calculates and displays quantitative results within seven minutes. Up to 16 results can be stored in the memory, making recordkeeping very convenient. Other features include screen display of all instructions, calibration status, testing information, and results.

Call us today to learn more about the Siemens/Bayer DCA 2000+ Analyzer!

Siemens/Bayer DCA 2000+ Analyzer Specifications

Siemens/Bayer DCA 2000+
Dimensions (HxWxD) 23.9 x 24.1 x 27.2 (cm)
9.4 x 9.5 x 10.7 (in)
Weight 11.0 lb (5.0 kg)
Power 100V to 240V (O.4A) 50/60 Hz
Ambient Operating Temperature Range 15 to 32 deg C (59 to 90 deg F)
Ambient Operating Humidity Range 10% to 90% (non-condensing)
Hemoglobin A1c (HBA1c) Yes
Reagent Supply (Detection) Yes
Testing Technique (Detection) Latex immunoagglutination inhibition methodology (HbA1c), immunoturbidimetric, agglutination complex (microalbumin), Benedict/Behre chemistry (creatinine)
Attributes Individually foil-wrapped reagent cartridges; memory stores 16 test results, 16 control results; factory bar code calibration; microalbumin/creatinine, microalbumin, creatinine with ratio; 4 reagent calibrations (2 HBA1c and 2 Malib/Creat)
Configuration Benchtop
Computer Interface RS232
Refrigerated (Tests) Reagents stable for 3 months at room temperature
Printer (External Beam) Equipped with Centronics/parallel port
Sample Required Whole blood, finger prick or venipuncture
Sample Volume (µl) 1
Performance Time 6 min.
FDA Clearance (Interference Compensation) Yes
CE Mark (MDD) (Interference Compensation) Yes

Siemens Siemens WS-DCA2000+