HP 5890 Series Single Detector II GC System I

HP 5890 Series Single Detector II GC System I

Manufacturer:
GMI SKU#: 2171-30-0011
  • Classic Gold Standard Reliability on a budget
  • Over 50,000 sold worldwide
  • Up to two detector Two inlet capabilities
  • Choice of automated sampling options
  • Compatible with multiple data analysis software packages
  • Electronic pressure control option
  • GMI can service your 5890 for years to come !
  • GMI offers installations and full service options

For more information or to place an offline order call 1-800-745-2710

OR
Description

HP 5890 Series II GC system with single detector (choice of FID or TCD)
System is refurbished to specification & is GMI Certified 

Includes:

• HP 5890 Series II Gas Chromatograph
• Single Split Splitless Inlet
• Single detector choice  (TCD or FID)
• 7673B Autosampler, tower, 100 sample tray, & controller
• Computer Data System (Win 7 PC) with preinstalled software 
• Flat panel 17" monitor, keyboard, mouse
• All cables, electronically supplied manuals, & complete performance documentation 

$ Call your sales representative for a customized quote on this Certified Pre-Owned HP 5890 Series GC system! 

Your GMI recertified GC system was refurbished to specification and tested by manufacturer trained engineers ! Installation (optionally) available. 

GMI has sold defect free HP 5890 series II GC Systems for 20 years and currently has on-hand inventory to build virtually any configuration. 

Why buy a classic Hewlett Packard 5890 series GC? Other than a more economical solution compared to a 6890 or 7890…… 

The Hewlett Packard 5890 and 5890 II series continues to be the gold standard of reliability for gas chromatography and is still used by tens of thousands of scientists in thousands of laboratories worldwide.

HP 5890 series II and 5890 series II Plus GCs can be used reliably to analyse chemical components of complex samples in industry, toxicology, drug screening, food safety, forensics, as well as general chemical analysis. Each instrument can be configured to fit your specific analytical needs and budget. Remember that 75% of all routine analysis can be done just as well on a HP 5890 as on the next generation 6890 series with no degradation in the data obtained. The 5890 is a PROVEN workhorse! While the HP 5890 Series II Plus is specifically designed for Electronic Pressure Control (EPC), the classic HP 5890 Series II system will adequately accommodate 90% of all applications. This model gas chromatograph boasts of five inlet and six detector options as well as several control and pressure elements. Additional options include gas sampling valves and both liquid and headspace auto samplers as well as packaged with Chromperfect® control and analysis software running on Windows 10 ! This GC Instrument compatible with *Chemstation, or NEW Data (Award winning Chromperfect for Windows 10) Analysis Software, or DataApex Clarity 

GMI supplied 5890 series GCs can provide users with options for columns, detectors and inlets to heighten equipment versatility. 

Listed below are common GMI supplied configurations of the Hewlett Packard 5890 II Series:

• 5890 Series II single injector (split/split less or Packed) single FID detector
• 5890 Series II single injector (split/split less or Packed) single TCD detector
• 5890 Series II dual injectors (split/split less or Packed) dual FID detectors
• 5890 Series II dual injectors (split/split less or Packed) dual TCD detectors
• 5890 Series II dual injectors (split/split less or Packed) dual FID/TCD detectors 

Need a mass selective detector?  No problem, why not consult your sales engineer today.

NOTE:  GMI no longer recommends purchase of 5890 Series GCs with ECD detectors. Such are END OF LIFE CYCLE . 

GMI only promotes safe sustainable solutions. 

Choose a 6890 series model if an ECD is required. 

Did you know that GMI offers complete and comprehensive maintenance and support plans?
– your choice- for one instrument or dozens-one facility or multi-site labs. 

Financing?  Rentals or Lease? No problem. We’d love to help with your financing or rental needs.

Thank you once again for considering purchasing this re-certified, refurbished-to-specification, HP GC from GMI. For over 20 years and over 100 installations- GMI removes 100% of the risk in ‘buying used’ chromatography instrumentation to discerning scientists like you. 

GMI is a ISO 9001:2008 certified companyyour proof that your instrument purchase from GMI passes through rigorous refurbishing, recalibration, and recertification process, arriving at your laboratory in fully working order and defect free. We are not an auction company, and we nor are we an instrument broker… getting in the middle of ‘deals’. All items come complete with the final QC date, engineer’s ID#, and a copy of test results / QC data, if applicable. Additionally, all items are thoroughly cleaned and professionally packaged / crated with care to ensure they arrive safely in your lab ready for professional installation. 

Service, Parts, Relocations, Installations, Validations, Buy, Sell, Rent, Lease – one call does it all from GMI 

Do you own an 5890 and want to ‘move up’ to a newer system? Your 5890 may be eligible for the GMI “Trade-In Trade-up Program” 

 Ask your representative today how to save on a newer GC system from GMI !

Specification
Inlet Options • 5890 PI (Packed Inlet)
• 5890 SSI (Split/Splitless Capillary Inlet)
• 5890 Temperature Prog. On-Column Inlet
• 5890 Split/Splitless Inlet w/EPC
• 5890 Temp Prog. On-Column Inlet w/EPC Split-only capillary
• Programmable Cool On- Column capillary (PCOC) (The PCOC injector is useful for biodiesel applications
Detector Options • 5890 FID (Flame Ionization Detector)
• 5890 TCD (Thermal Conductivity Detector)
• 5890 ECD (Electron Capture Detector)
• 5890 FPD (Flame Photometric Detector)
• 5890 NPD (Nitrogen Phosphorous Detector)
Split/Splitless Capillary • Range to 400°C in 1°C increments
• Back-pressure design permits independent adjustment of split flow rate without affecting column flow
• Septum purge built in at 3 ml/min
• Accepts columns up to 1.2-mm od
• Multimode design includes split and splitless injection
• Splitless purge time variable in 0.01-min elements
Flame Ionization Detector  • Range to 450°C
• Grounded jet and current limited design for operator safety
• Push-button flame ignition
• Sensitive:
  o 18 mCoul/gm carbon: nitrogen carrier, 0.018-in. id jet
  o 15 mCoul/gm carbon: helium carrier, 0.018-in. id jet
  o 22mCoul/gm carbon: nitrogen carrier, 0.018-in. id capillary jet
  o 18 mCoul/gm carbon: helium carrier, 0.018-in. id capillary jet
  o Minimum detectable: 5 pg carbon/sec, nitrogen carrier at S/N=2
  o Linear dynamic range: +/- 10% over a 10 7 range with 0.018-in. id jet
  o Conditions: column flow 50 ml/min, 45 ml/min H2, 650 ml/min air, propane sample
Thermal Conductivity Detector • Range to 400 °C
• Single-filament (single column) design has fluidic switching of reference and analytical carrier flows
• Minimum detectable :400 pg/ml carrier -- equivalent to 1 pmm neon in 1 ml air
• Linear dynamic range:+/- 5% over 105 range
• Digital gain setting time-programmable through the keyboard Conditions: detector
• 100 °C, 45 ml/min switching and 30 ml/min analytical flow of helium, propane sample
Column Oven • Operating range: 4 °C above ambient to 450 °C
• Setpoint entry: 1 °C for temperatures, 0.1 °C for program rates
• Programming: Rates 0.1 to 70 °C per min, 650 min maximum run time, Three ramps with initial/final holds
7673B Autosampler Includes Injection tower, 100-sample tray and controller, INET Communications
Services
GMI Certified Service means:
  • Healthy operation of your instrument
  • Helping to ensure the quality of your results
  • Lowering cost of ownership through multilple service agreement options
  • Prolonging instrument serviceable life
  • Safe Operation of your equipment
  • Minimizing downtime increases productivity and minimizes revenue loss
  • Instrument Evaluation Services
  • Contract Refurbishing
  • Relocation Services
  • Equipment Finder Service
  • Training Courses
  • Depot Repair
  • Instrument Decommisioning & Disposal Services
Service Agreements


Bronze
Prevention
Plus
Silver
Assurance
Plus
Gold
Safety
Plus
Platinum
Premium
Plus
PM
Preventative Maintenance Visit
('tune up', including cleaning, lubrication, and adjustments)
1PM
or
1 Service Visit
Service Visit 1PM
or
1 Service Visit
1 2
Travel
Parts and Labor    

1 YEAR
Discounted Parts
Discounted Labor (As needed)
Parts

Lab Equipment Replacement Parts & Accessories

Click button to view parts which are available for this instruments and instruments like it in our brand new online parts shop.

We also carry instruments parts for the following other instruments categories.

WHY BUY FROM GMI?

Your trusted source for new & used lab equipment and instrument service since 1995.

  • We routinely save discerning laboratories 50-80% off retail on our recertified instrument offerings.

  • Quality? ISO 9001:2008 certified means we remove 100% of the risk in buying ‘used’ laboratory equipment.

  • Warranties from 90 days to a year as well as multi-year service agreements are available.

GMI is an ISO 9001:2008 certified company - your proof that your instrument purchase from GMI passes through rigorous refurbishhing,recalibration, and recertification process,arriving at your laboratory in fully working order and defect free. We are not an auction company,and nor are we an instrument broker...getting in the middle of 'deals'. All items come complete with the final QC date, engineer's ID# and a copy of test results/QC data, if applicable. Additionally, all items are thoroughly cleaned and professionally packaged/crated with care too ensure they arrive in your lab ready for professional installation.