Hewlett Packard HP 5890 Series GC
Hewlett Packard HP 5890 Series GC
| Product Description |
The Hewlett Packard 5890 and 5890 II series continues to be reliable and extensively used Gas Chromatograph or GC systems in many laboratories. HP 5890 and 5890 II chemical analysis equipment can be used to take apart chemical components of complex samples utilized in toxicology, drug screening, food safety and law enforcement. Each unit can be fully configured to fit your analytical needs and budget.
While the HP 5890 Series II Plus is specifically designed for Electronic Pressure Control (EPC), the HP 5890 system is a flexible research tool that offers a variety of applications like basic system with pneumatics and injection in manual mode or electronic pressure control pneumatics and automatic sampling. This gas chromatograph boasts of five inlet and six detector options as well as several control and pressure elements. Additional features include four external event controls, three ramp oven programming controls, an analog output and an electronic control option.
Hewlett Packard Gas Chromatographs under the HP 5890 series have linear adapters that can provide users with options for columns, detectors and inlets to heighten equipment performance. Versatility of this laboratory equipment can be further enhanced by the relative positioning of the inlets and detectors to one another. Numerous options are available to construct the most appropriate Hewlett Packard 5890, HP 5890 II or HP 5890 Plus unit that will answer your specific analytical requirements.
Listed below are common configurations of the Hewlett Packard 5890 II Series
- 5890 Series II single injector (split/split less or Packed) single FID detector
- 5890 Series II single injector (split/split less or Packed) single TCD detector
- 5890 Series II dual injectors (split/split less or Packed) dual FID detectors
- 5890 Series II dual injectors (split/split less or Packed) dual TCD detectors
- 5890 Series II dual injectors (split/split less or Packed) dual FID/TCD detectors
Call us today to learn more about the Hewlett Packard 5890 series!
| HP 5890 Series II | HP 5890 Plus | |
| Height | 18-3/8 inches (465 mm) | 18-3/8 inches (465 mm) |
| Width | 25-7/8 inches (655 mm) | 25-7/8 inches (655 mm) |
| Depth | 20-1/8 inches (511 mm) | 20-1/8 inches (511 mm) |
| Weight | 90 lbs (41 kg) | 90 pounds (41 kg) |
| Voltages | 120/200/220/240 | 120/200/220/240 |
| Range | +5, - 10% each | +5, - 10% each |
| Frequency | 47.5 – 66 Hz | 47.5 – 66 Hz |
| Consumption | 2200 VA max | 2200 VA max |
| Output | 7500 Btu/hr max | 7500 Btu/hr max |
| Operating Range | 0-55°C ambient (20-27 °C optimum) 5-95% humidity (50-60% optimum) |
0-55°C ambient (20-27 °C optimum) 5-95% humidity (50-60% optimum) |
| Five heated zones standard | Two detectors Two inlets One auxiliary |
Two detectors Two inlets One auxiliary |
| Methods stored | Two | Two |
| Flow Sensor | ||
| Range Accuracy |
0-35 sccm [sccm = standard cc/minute] ±3 sccm for He and H2 ±5 sccm for N2 and ArCH4 |
N/ A |
| Extended range Accuracy |
100-150 sccm ±15 sccm |
N/ A |