Profile Informations

Login Datas

or login

First name is required!
Last name is required!
First name is not valid!
Last name is not valid!
This is not an email address!
Email address is required!
This email is already registered!
Password is required!
Enter a valid password!
Please enter 6 or more characters!
Please enter 16 or less characters!
Passwords are not same!
Terms and Conditions are required!
Email or Password is wrong!

GENESYS 5000 Series Multi-well Gamma Counters

GENESYS 5000 Series Multi-well Gamma Counters

Manufacturer: GENESYS
GMI SKU#: 8192-30-0020
  • Crossover Elimination Software
  • Selectable Window Settings
  • Automatic Spilldown Correction
  • A Unique Crystal Design

For more information or to place an offline order call 1-800-745-2710


The GENESYS 5000 Series Multi-well Gamma Counters are the most sophisticated gamma counters in the world. Available in 5- 10- 15- 20 or 25 wells- you will find a model that works for your medium to high volume laboratory.

The GENESYS 5000 Series gamma counters contain advanced data reduction features suitable for calculating all versions of RIA- IRMA- Ratio and Screening assays. With the flexibility to independently choose curvefit- response variable (transformation) and graph paper- the GENESYS 5000 gives you the power to adequately handle the wide range of radioimmunoiassays available for clinical and research applications; from the routine through the esoteric.

The range of popular curvefits include: point to point- straight line- weighted straight line- cubic spline- universal and four parameter logistic (4PL).

Response variables include: B/TC- B/B0- CPM- TC/B- B0/B- 1/CPM- CPM/(standard #)- CPM/ (High Standard)- CPM/(TC-CPM) and (TC-CPM)/CPM.

Standard curve axes choices are: Linear-Linear- semi-Log- Log-Log- Logit-Log- Linear-Log and Log-Linear.

The GENESYS 5000 Series has the unique capability of counting a wide variety of isotopes to provide flexibility beyond that of routine RIA's. Ten different isotopes may be programmed into the system.

Isotopes such as Cr51- I131- In111- Na22- and Fe59 are among some of the more common isotopes used in today's lab.

With this flexibility- Schilling and Blood Volume are easily run.

The GENESYS incorporates several features to make this possible:

makes counting high energy isotopes possible while still retaining all the precision and accuracy of a single well system. Any contributing activity which might "cross-over" from one well to the next- is monitored and subtracted out- without the need to "shut off" every other detector.

allow the user to set upper and lower windows up to 1000 KEV. With this option- you can set a wide window to scan unknowns for any interfering isotopes.

is applied to each well when running dual label assays to account for any spilldown of the high energy isotope into the lower energy window. Any two isotopes may be counted simultaneously.

enables the GENESYS to count high energy isotopes without the need for extremely large diameter detectors. Having many wells counting simultaneously- along with the high efficiency design of our crystals greatly increases the throughput.

With this variety of choices- even the most demanding applications can be met with ease. A brief description of each curvefit algorithm follows:

Point to Point:
This curve fit connects adjacent standard points with a straight line. This is a "connect the dots" approach- and is quite commonly used in older software packages and for connecting particularly difficult data. This curve fit is best used when there are many standard points within the curve- or when there is a very sharp change in slope. This curvefit minimizes curvature errors.

Straight line:
This curvefit utilizes a single- straight line to fit all standard points within the curve. This fit- therefore- requires that all points on the curve be first "linearized". This is most often accomplished by using a Logit-Log or/Bound type of transformation. By first linearizing the data- fitting errors will be minimized.

Weighted Straight Line:
This curvefit begins as a straight line- then adds "weighting factors" as needed. These weighting factors are particularly helpful to minimize the effect of stray points which are further from the most stable portion of the curve (mid dose). The weighting factor changes the slope of the curve to maximize the influence on the mid-dose area of the curve.

Cubic Spline:
The Cubic Spline is actually not a single curve- but rather a series of curvilinear segments- which are joined together at "knots". These knots are the standard points. Therefore- the overall curve must pass through the mean of each of the standard points exactly. The cubic spline fit is very commonly used in IRMA assays- where a larger number of standard points is typical. Due to the nature of the cubic spline equation- the standard curve must contain at least 4 points in order to fill the equation.

Universal Curve:
The Universal Curve found in the Genesys 5000 series gamma counter is an extension of the basic cubic spline with some very unique differences. The Universal Curve utilizes the statistical uncertainties of each standard point in the curve to allow a "range" into which to fit the curve- rather than force it through the mean. Because of this statistical "smoothing" function- the Universal Curve has the ability to fulfill a much wider range of data than the standard cubic spline. The Universal Curve can be specifically useful in IRMA assays which involve very low count standard points at low dose. Since the uncertainty is greatest near the extremities of the curve and particularly the area of lowest count rate- this region logically should impact the shape of the overall curve the least. Thus- the Universal Curve compensates for these inaccuracies by extending the range through which the curve is fit- thereby greatly improving the overall performance of the assay as a whole.

Four Parameter Logistic:
The four parameter logistic curve fit is based upon the "All Fit" program originally developed at NIH. It is basically an extension of the two parameter Logit-Log method. By its nature- the 4PL- like the cubic spline must have at least four standard points in order to plot a curve. The four parameter is the most "robust" of all the curve fits- and is the most widely suitable for a variety of applications from sigmoidal or J-shaped RIA's to high sensitivity IRMAs.

The nature of the 4PL equation requires that the GENESYS 5000 SERIES gamma counters perform many iterations of highly complex calculations in order to achieve the best fitting curve. It is therefore common to wait A second or two for the curve to calculate.

GMI Certified Service means:
  • Healthy operation of your instrument
  • Helping to ensure the quality of your results
  • Lowering cost of ownership through multilple service agreement options
  • Prolonging instrument serviceable life
  • Safe Operation of your equipment
  • Minimizing downtime increases productivity and minimizes revenue loss
  • Instrument Evaluation Services
  • Contract Refurbishing
  • Relocation Services
  • Equipment Finder Service
  • Training Courses
  • Depot Repair
  • Instrument Decommisioning & Disposal Services
Service Agreements

Preventative Maintenance Visit
('tune up', including cleaning, lubrication, and adjustments)
1 Service Visit
Service Visit 1PM
1 Service Visit
1 2
Parts and Labor    

Discounted Parts
Discounted Labor (As needed)

Lab Equipment Replacement Parts & Accessories

Click button to view parts which are available for this instruments and instruments like it in our brand new online parts shop.

We also carry instruments parts for the following other instruments categories.


Your trusted source for new & used lab equipment and instrument service since 1995.

  • We routinely save discerning laboratories 50-80% off retail on our recertified instrument offerings.

  • Quality? ISO 9001:2008 certified means we remove 100% of the risk in buying ‘used’ laboratory equipment.

  • Warranties from 90 days to a year as well as multi-year service agreements are available.

GMI is an ISO 9001:2008 certified company - your proof that your instrument purchase from GMI passes through rigorous refurbishhing,recalibration, and recertification process,arriving at your laboratory in fully working order and defect free. We are not an auction company,and nor are we an instrument broker...getting in the middle of 'deals'. All items come complete with the final QC date, engineer's ID# and a copy of test results/QC data, if applicable. Additionally, all items are thoroughly cleaned and professionally packaged/crated with care too ensure they arrive in your lab ready for professional installation.