Registration

Profile Informations

Login Datas

or login

First name is required!
Last name is required!
First name is not valid!
Last name is not valid!
This is not an email address!
Email address is required!
This email is already registered!
Password is required!
Enter a valid password!
Please enter 6 or more characters!
Please enter 16 or less characters!
Passwords are not same!
Terms and Conditions are required!
Email or Password is wrong!

Agilent 1100 LC MSD Model G1946D Mass Spectrometer

Agilent 1100 LC MSD Model G1946D Mass Spectrometer

Manufacturer:
GMI SKU#: 8012-30-1296
  • Agilent 1100 LC/MSD Model G1946D
  • ElectroSpray ionization Source
  • Mass Range 2-3000 amu
  • LAN Communications
  • Roughing Pump
  • Complete Data system

For more information or to place an offline order call 1-800-745-2710

OR
Description

Agilent 1100 LC/MSD with Model G1946D mass spectrometer.
Agilent 1100 G1956D LC MS  refurbished to specifications, ESI source, roughing pump, complete data system.  *Professional installation available.

In 1997 HP introduces its first benchtop quadrupole LC/MS the 1100 Series LC/MSD. The 1100 Series LC/MSD provides information quickly in one chromatographic run. It provides molecular weight structural information and has excellent selectivity needed to identify compounds check the purity of chromatographic peaks and quantitate trace level samples in complex matrices in a rugged reliable easy-to-use benchtop system. For chromatographers and mass spectrometrists who need the utmost in sensitivity the LC/MSD SL makes analyses in the very low picogram range possible*

The 1100 Series LC/MSD offers many advantages as an LC detector. It offers the dynamic range and repeatability needed for most quantitative applications. In the SIM mode it offers high sensitivity. For compounds lacking a strong chromophore it offers detection limits not possible with other detectors. By offering unit mass resolution to m/z 3000 the LC/MSD allows for characterization of large proteins beyond 60000 KDalton. Having extended mass range to 3000 is also beneficial when studying modified proteins such as glycoproteins where their charge distribution falls above m/z 2000.

The Agilent 1100 Series LC/MSD is a benchtop mass spectrometer designed to be integrated with the 1100 Series HPLC System. It is a quadrupole based atmospheric pressure ionization (API) instrument capable of doing both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). The LC/MSD can handle normal HPLC flow rates (1 ml/min) without splitting the effluent and with minimal adjustment of the spray chamber.

Optional Configuration

  • Agilent/HP 1100 Series G1312A Binary Pump
  • Agilent/HP 1100 Series G1313 Autosampler
  • Agilent/HP 1100 Series G1316A Column compartment
  • Agilent/HP 1100 Series G1322A Degasser and Solvent tray
  • More Configurations available

Pharmaceutical

Mass spectrometry plays an important role in the entire life cycle of a drug from discovery to development to manufacturing. In drug discovery LC/MS systems are the method of choice for identifying and characterizing of drug candidates produced by combinatorial chemistry or extracted from natural products. They are also a primary tool used to check drug compound quality during manufacturing.

Proteomics

Proteomics is the large-scale analysis of proteins for disease research and drug discovery. MS analysis is a fundamental tool for proteomic research. In addition to LC/MS instruments for identifying and quantifying proteins in biological samples Agilent has developed wide range of complementary technologies to help researchers prepare separate analyze identify and interpret challenging protein samples.

Metabolomics

This rapidly growing area of life science research is the study of small molecules known as "metabolites" which are products of metabolism in tissues. The makeup of these sets of molecules is increasingly being associated with a number of illnesses. GC/MS and LC/MS are the main analytical techniques to detect and measure large numbers of metabolites. Agilent also offers the METLIN personal metabolite database to help users identify the metabolites they find and profiling software to compare large sets of metabolite data to one another.

Environmental

The ability to identify and quantify pollutants is essential to maintaining a health environment. A mainstay of environmental testing GC/MS is used to detect volatile organic compounds such as pesticides. Agilent is the worldwide leader in GC/MS. Inductively coupled plasma mass spectrometry (ICP-MS) helps identify and quantify inorganic compounds and heavy metals. LC/MS is a popular complement to GC/MS; it can analyze more fragile chemicals that may not stand up well to GC/MS analysis.

Food safety:

GC/MS LC/MS and ICP-MS are widely employed for food safety testing which includes the analysis of additives residues contaminates and toxins in agricultural products and foods. The need for food testing is growing rapidly driven by the liberalization of global trade a more stringent regulatory environment and increased public awareness of food safety issues.

Applications

Mass spectrometry has long been a mainstay in applications that involve the analysis of small thermally stable organic compounds inorganic compounds and metals. More recently the development of new technology has dramatically increased the ability of mass spectrometers to analyze large relatively fragile biological molecules such as proteins opening vast new applications for MS. Important applications and markets for MS include:

Forensics

Agilent is the worldwide leading provider of GC/MS systems for drug screening and toxicology. As with the environmental industry Agilent LC/MS systems are beginning to be employed for forensic analyses as a complement to GC/MS. ICP-MS coupled to laser ablation (LA-ICP-MS) is also useful for measuring solid samples as well as for elemental fingerprinting of materials in forensic investigations

Hydrocarbon Processing Industries (HPI)

HPI comprises the petroleum petrochemical fine and specialty chemical natural gas industrial gas and fuel cell industries. Agilent mass spectrometers particularly GC/MS systems are routinely used process performance in QA/QC and process control.

Specification

Agilent 1100 LC MSD Model G1946D Mass Spectrometer Specifications

Mass Range2-3000 amu
Mass Accuracy+/- 0.13 u within the calibrated mass range in scan mode
Mass Axis Stability+/- 0.13 u over 8 hours
Scan Speed2500 u/s standard mode
5250 u/s fast scan mode
SIM SensitivityESI at 400 ul/min
APCI at 1000 ul/min
Selected ion monitoring of m/z 609.3
Positive ionization
Signal To Noise Ratio
Quantity: 1 pg reserpine 100:1 RMS (20:1 peak-to-peak)
Scan SensitivityESI at 400 ul/min
APCI at 1000 ul/min
Scan range m/z 100-650
Scan speed 2500 u/s
Extracted ion at m/z 609.3
Positive ionization
Signal To Noise Ratio
Quantity: 50 pg reserpine 100:1 RMS (20:1 peak-to-peak)
Multiple Signal AcquisitionAbility to cycle
Services
GMI Certified Service means:
  • Healthy operation of your instrument
  • Helping to ensure the quality of your results
  • Lowering cost of ownership through multilple service agreement options
  • Prolonging instrument serviceable life
  • Safe Operation of your equipment
  • Minimizing downtime increases productivity and minimizes revenue loss
  • Instrument Evaluation Services
  • Contract Refurbishing
  • Relocation Services
  • Equipment Finder Service
  • Training Courses
  • Depot Repair
  • Instrument Decommisioning & Disposal Services
Service Agreements


Bronze
Prevention
Plus
Silver
Assurance
Plus
Gold
Safety
Plus
Platinum
Premium
Plus
PM
Preventative Maintenance Visit
('tune up', including cleaning, lubrication, and adjustments)
1PM
or
1 Service Visit
Service Visit 1PM
or
1 Service Visit
1 2
Travel
Parts and Labor    

1 YEAR
Discounted Parts
Discounted Labor (As needed)
Parts

Lab Equipment Replacement Parts & Accessories

Click button to view parts which are available for this instruments and instruments like it in our brand new online parts shop.

We also carry instruments parts for the following other instruments categories.

WHY BUY FROM GMI?

Your trusted source for new & used lab equipment and instrument service since 1995.

  • We routinely save discerning laboratories 50-80% off retail on our recertified instrument offerings.

  • Quality? ISO 9001:2008 certified means we remove 100% of the risk in buying ‘used’ laboratory equipment.

  • Warranties from 90 days to a year as well as multi-year service agreements are available.

GMI is an ISO 9001:2008 certified company - your proof that your instrument purchase from GMI passes through rigorous refurbishhing,recalibration, and recertification process,arriving at your laboratory in fully working order and defect free. We are not an auction company,and nor are we an instrument broker...getting in the middle of 'deals'. All items come complete with the final QC date, engineer's ID# and a copy of test results/QC data, if applicable. Additionally, all items are thoroughly cleaned and professionally packaged/crated with care too ensure they arrive in your lab ready for professional installation.