You are here: GMI Clinical Hematology Hematology Analzyers Sysmex XT 2000i Automated Hematology Analyzer

New and Used Lab Equipment - GMI Inc

Loading
Clinical arrow Hematology arrow Hematology Analzyers arrow Sysmex XT 2000i Automated Hematology Analyzer (sys2000xt)

Sysmex XT 2000i Automated Hematology Analyzer

Sysmex XT 2000i Automated Hematology Analyzer

  • Built on the modern fluorescent flow cytometry platform of the SYSMEX XE-2100
  • Reliable system requiring minimum maintenance (just one shut-down cycle/day)
  • Excellent WBC differential with low review rate due to fluorochrome staining of cells
  • Four random access selective test profiles (CBC, CBC/DIFF, CBC/RET, CBC/DIFF/RET)
  • Real time bi-directional host communication
  • Network capability for integration into a productive laboratory environment
  • Fluorescent optical platelets for accurate platelet counts even in case of small RBC or large PLT
  • Cumulative patient data and Delta Check
  • Comprehensive software programs for internal and external quality control on board
... Full Description >>>


Complete Product Description

Sysmex XT 2000i Automated Hematology Analyzer

  • Built on the modern fluorescent flow cytometry platform of the SYSMEX XE-2100
  • Reliable system requiring minimum maintenance (just one shut-down cycle/day)
  • Excellent WBC differential with low review rate due to fluorochrome staining of cells
  • Four random access selective test profiles (CBC, CBC/DIFF, CBC/RET, CBC/DIFF/RET)
  • Real time bi-directional host communication
  • Network capability for integration into a productive laboratory environment
  • Fluorescent optical platelets for accurate platelet counts even in case of small RBC or large PLT
  • Cumulative patient data and Delta Check
  • Comprehensive software programs for internal and external quality control on board

Technologies: Fluorescent Flow Cytometry method: WBC-DIFF, reticulocytes, PLT-O, IG DC sheath flow method: RBC, HCT, PLT, cyanide-free SLS method: HGB

Parameters:WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT Neut%, Lymph%, Mono%, Eo%, Baso% Neut#, Lymph#, Mono#, Eo#, Baso# RDW-SD, RDW-CV, MPV, RET%, RET#, IRF

Throughput: Stand-alone: 80 samples/hour TWIN: 160 samples/hour

Aspiration Volume: Sampler or manual closed mode: 150μL manual open mode: 85μL capillary mode: 40μL

Data Storage: 10,000 samples (incl. graphics) 5,000 patients' information 1,000 selective test orders

Quality Control: Comprehensive QC files including "Current" and "New" lot feature 1 XbarM file with 300 data points Online QC

Interfaces: Host, line printer, graphic printer

Dimensions/Weights:
Main Unit: 20.x x 24.8 x 19.7 / 114.6
Sampler: 20.5 x 8.7 x 4.3 / 15.4
Pneumatic Unit: 11.2 x 14 x 15.8 / 35.3