Chromatography
GC - Gas Chromatography
GC - Gas Chromatography System
SRI 8610C (GC) Gas Chromatograph
(SRIGC8610)
The SRI 8610C GC can mount up to an astonishing six detectors, easily accommodating your FID, FPD, PID, and ECD needs. Up to a possible five injectors facilitate all your Split/ Split-less, Purge and Trap needs.
As if these benefits were not enough the 8610 Gas Chromatograph from SRI remains small enough to ship or even check in to your airline baggage. Its small footprint allows it to fit into any crowded laboratory and can be easily shipped for service.
![]() | With SRI, configurability is not compromised by support. There are sixteen detector choices and 12 injectors to choose from. Contact our highly trained sales or service team to assist you in configuring a system for your specific needs. The SRI 8610C unit has a column oven with a programmable temperature range of ambient through to 400 C. There are no restrictions in ramps and a fast cool down feature is available. The air bath can hold a mega bore column cage up to 7 inches in diameter. Alternatively, multiple columns with smaller coil sizes may also be used. SRI has designed this system to be configurable with almost any EPA or ASTM method. |
SRI specializes in custom gas chromatographs, but GMI can offer many preconfigured GCs for common applications. Each GC includes a built-in PeakSimple data system with software, and connects to your Windows computer with a USB 2.0 cable (requires USB 2.0 compliant port on PC).
Below are a selection of pre- configured systems ready for your laboratory.
| Capillary FID GC General purpose GC | Multiple Gas Analyzer + Sulfur GCs For H2S, SO2, fixed gases and C1-C20 hydrocarbons | Explosives GC For nitro-aromatic and nitramine explosives in the field |
| Narrow Bore Capillary FID GC For semi-volatiles and high boiling compounds | Natural Gas Gas Analyzer GC For compositional analysis of natural gas | HVROC GC For ethylene, propylene, 1,3-butadiene and butenes, which play a role in rapid ozone formation |
| CryoSulfur GC For trace sulfur in gas or liquid | Method 25 Methane/Nonmethane GC For methane/nonmethane hydrocarbons as per EPA Method 25 | Biodiesel GC For free and total glycerol in B-100 biodiesel, as per ASTM D-6584, EN 14105 |
| Greenhouse Gas Monitoring GC For greenhouse gases methane, carbon dioxide and nitrous oxide | Mud-Logging GC For total hydrocarbons plus detailed C1-C6 content | PCB GC For PCBs in soil and other solid matrices |
| DGA GC For dissolved gases in water and other liquids | Rack Mount Mud-Logging GC For 19 inch shelf equipped racks | 310 Soil Gas GC For soil and gas investigation applications |
| Multiple Gas Analyzer #1 GC For fixed gases and light hydrocarbons | TO-14 Air Monitoring GC For EPA air monitoring methods | Gas-less™ Educational CCD GC For teaching GC without using compressed gases—right in the classroom |
| Multiple Gas Analyzer #2 GC For fixed gases, water and hydrocarbons to C20 | Environmental and BTEX GCs For most EPA series 8000 methods | Educational TCD GC For demonstrating gas chromatography on the same equipment students will encounter in industry |
| Multiple Gas Analyzer #3 GC For fixed gases, water and hydrocarbons to C20, improved design at a lower price than MG#2 | Geoprobe™ GC For continuous VOC measurement and speciation of Geoprobe purge gas | Educational FID GC For teaching undergraduate gas chromatography, or for graduate research |
| System | |
| Detectors | 6 |
| Diameter | 5 |
| Width | 19 inch |
| Height | 13.5 inch |
| Depth | 14.5 inch |
| Detector | Combined FID/TCD |
| Temp range | 25 to 400°C |
| Temp control | programmable, up to 15 ramp and dwell times |
| Stability | ±0.1°C |
| Heating rate | 50°C per minute to 300°C; 20°C per minute from 300 to 400°C |
| Cooling rate | 300 to 50°C in 5 minutes |
| Gas flow control | electronic pressure control |
| Power | 115V 50/60 Hz |