We respect your privacy, we do not disclose to 3rd parties.
  • designed to provide a continuous reading of total hydrocarbons in a gasstream while periodically performing a chromatographic separation of the sample to determine the compositionof the sample gas stream.
  • 10 port Gas Sampling Valve with a 25μL Sample Loop
  • can be modified to incorporatea second FID instead of the CCD
  • ...on the compact 8610C chassis
Product Description

The Mud-Logging GC system is designed to provide a continuous reading of total hydrocarbons in a gas stream while periodically performing a chromatographic separation of the sample to determine the composition of the sample gas stream. This is accomplished using a 10 port Gas Sampling Valve with a 25μL Sample Loop in a thermostatted Valve Oven a 1m (3’) Hayesep D packed column in a temperature programmable Column Oven a CCD detector an FID detector and a built-in Air Compressor. This GC can be modified to incorporate a second FID instead of the CCD for total hydrocarbon monitoring. The model shown below has CCD and FID detectors.

 

 

Speciation of C1-C6 hydrocarbons is handled by the Gas Sampling Valve Hayesep-D column and FID while the CCD provides contiuous total hydrocarbon monitoring. Detection limits for this system are 0.1% to 100% for the continuous total hydrocarbon monitor and 0.005% to 100% for speciated hydrocarbons using the FID. The Air Compressor supplies combustion air for the FID and the air make-up for the CCD. The built-in PeakSimple data system displays both the continuous total hydrocarbon reading using the Data Logger mode and the separated peaks. When the system receives out-of-range readings an alarm function may alert the user.

 

 SRI 8160 SRI Gas Chromatograph Mud-Logger Systems Specifications

System
Width 19 inch
Height 13.5 inch
Depth 14.5 inch
Detector Combined FID/TCD
Temp range 25 to 400°C
Temp control programmable up to 15 ramp and dwell times
Stability ±0.1°C
Heating rate 50°C per minute to 300°C; 20°C per minute from 300 to 400°C
Cooling rate 300 to 50°C in 5 minutes
Gas flow control electronic pressure control
Power 115V 50/60 Hz

SRI SRI SRIGC8610MUD