Bio Data Platelet PAP 4-C Aggregation Profiler

The PAP-4C is a four channel Platelet Aggregation Profiler with four test modes are available: Chromogenic Assays, von Willebrand Assay (Ristocetin Cofactor), Platelet Aggregation and Leukocyte Aggregation.
The PAP-4C may also be used for the evaluation and confirmation of Heparin Induced Thrombocytopenia (HIT). Four channels allow four tests to be run simultaneously and independently.

 

 

 

 

 





Bio Data Platelet PAP 4-C Aggregation Profiler

Features:

Chromogenic Assay
Centralizes chromogenic assays such as Anti-Thrombin III, Plasminogen, Protein C, Heparin and Factor Xa on one instrument
Unified procedure measures initial rate reaction, plots the standard curve and calculates results automatically
Reduces reagents to microplate quantities and eliminates the need for sample and reagent blanks
Stores up to eight standard curves in memory of future use

von Willebrand Assay (Ristocetin Cofactor)
Calculates and plots "best fit" standard curve
Reports test results in percent activity
Stores von Willebrand Factor standard curve for future use
Prints data on log-log chart

Platelet Aggregation
Four channels allow simultaneous performance of a routine aggregation profile    Automatic 0% - 100% baseline settings
Reports slope value and final percent aggregation
Prints aggregation patterns in real time

Leukocyte Aggregation
Adjustable stir speed settings meet method-specific RPM requirements
Convenient four channel setup for dose response studies of chemotactic stimuli or  pharmaceutical agents
Provides percent transmission for cell suspension standardization
Maintains optimum temperature for cell viability and reactivity

Heparin Induced Platelet Aggregation (HIPA) for Heparin-Induced Thrombocytopenia (HIT) Four channels allow simultaneous monitoring of the patient plasma sample and the recommended controls
Different heparin concentrations can be used to increase sensitivity
Permits the use of Arachidonic Acid Reagent to confirm platelet viability and functional status

You can reserve/order this instrument by calling 763-712-8717 or by completing the form on the Ordering Page



 


 
  Accepting all major credit cards:  At GMI...its instrumental !

  GMI, Inc.
  6511 Bunker Lake Blvd.  
  Ramsey, Minnesota, 55303   USA
  Tel. 763-712-8717          Fax 763-712-8724 
 
Send electronic mail to richard@gmi-inc.com

 

Copyright © 1998 - 2006  This page and all associated pages (and their HTML) of this website and all content at www.gmi-inc.com are the sole property of Global Medical Instrumentation, Inc. and are protected by GMI copyright protection laws and may not be reproduced in any form nor may any content or any  images be removed without the owner's express written permission. All instruments mentioned on our web site are the trademarks of their respective manufacturer.  GMI, Inc. makes no claims of special affiliation with or special sanctions by the original manufacturers or their respective trademarks. The appearance of those names is not intended to imply that GMI  is an officially authorized dealer or distributor for those manufacturers .   Purchases are subject to GMI Terms and Conditions of Sale found on our Contact and Ordering page. 
***Inventory changes daily, please call for availability and for items not seen or listed.   We look forward to hearing from you!