Genesys 5000 Multi Well Gamma Counter
The GENESYS 5000 Series
Multi-well Gamma Counters are the most sophisticated gamma
counters in the world. Available in 5, 10, 15, 20 or 25 wells, you
will find a model that works for your medium to high volume
laboratory.
The GENESYS 5000 Series gamma counters contain advanced data
reduction features suitable for calculating all versions of RIA,
IRMA, Ratio and Screening assays. With the flexibility to
independently choose curvefit, response variable (transformation)
and graph paper, the GENESYS 5000 gives you the power to adequately
handle the wide range of radioimmunoiassays available for clinical
and research applications; from the routine through the esoteric.
The range of popular curvefits include: point to point, straight
line, weighted straight line, cubic spline, universal and four
parameter logistic (4PL).
Response variables include: %B/TC, %B/B0, CPM, TC/B, B0/B, 1/CPM,
CPM/(standard #), %CPM/ (High Standard), CPM/(TC-CPM) and (TC-CPM)/CPM.
Standard curve axes choices are: Linear-Linear, semi-Log, Log-Log,
Logit-Log, Linear-Log and Log-Linear.
The
GENESYS 5000 Series has the unique capability of counting a wide
variety of isotopes to provide flexibility beyond that of routine
RIA's. Ten different isotopes may be programmed into the system.
Isotopes such
as Cr51, I131, In111, Na22, and Fe59 are among some of the more
common isotopes used in today's lab.
With this
flexibility, Schilling and Blood Volume are easily run.
The
GENESYS incorporates several features to make this possible:
1.
CROSSOVER ELIMINATION SOFTWARE makes counting high energy
isotopes possible while still retaining all the precision and
accuracy of a single well system. Any contributing activity which
might "cross-over" from one well to the next, is monitored and
subtracted out, without the need to "shut off" every other detector.
2.
SELECTABLE WINDOW SETTINGS
allow the user to set upper and lower windows up to 1000 KEV. With
this option, you can set a wide window to scan unknowns for any
interfering isotopes.
3.
AUTOMATIC SPILLDOWN CORRECTION
is applied to
each well when running dual label assays to account for any
spilldown of the high energy isotope into the lower energy window.
Any two isotopes may be counted simultaneously.
4. A
UNIQUE CRYSTAL DESIGN
enables the GENESYS to count high energy isotopes without the
need for extremely large diameter detectors. Having many wells
counting simultaneously, along with the high efficiency design of
our crystals greatly increases the throughput.
|