You are here: GMI Biotech Molecular Imaging Molecular Dynamics Typhoon 9410 Molecular Imager

New and Used Lab Equipment - GMI Inc

Loading
Biotech arrow Molecular Imaging arrow Molecular Dynamics Typhoon 9410 Molecular Imager (WS-S9410)

Molecular Dynamics Typhoon 9410 Molecular Imager

  • Versatile system handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.
... Full Description >>>


Complete Product Description

MOLECULAR DYNAMICS Typhoon™ 9410 and PC Workstation

MOLECULAR DYNAMICS (GE) Typhoon 9410 high performance gel and blot imager that can also perform image micro-arrays.

Molecular Dynamics (GE) Typhoon™ 9410 Variable Mode Imager unites proven storage phosphor auto-radiography technology with four-color, non-radioactive fluorescent labeling techniques. For DNA, RNA, and protein samples with the Molecular Dynamics Typhoon 9410, you may choose from:
  • storage phosphor auto-radiography
  • direct blue-excited fluorescence (457, 488 nm)
  • direct green-excited fluorescence (532 nm)
  • direct red-excited fluorescence (633 nm)
  • chemiluminescence
When one of the scanning modes is selected, the Typhoon 9410 activates the appropriate optical components are automatically. Typhoon 9410 scans gels, blots, and mounted or unmounted storage phosphor screens up to 35 × 43 cm. The Typhoon 9410 exhibits outstanding linearity, quantitative accuracy, and extremely low limits of detection.

Choose from four different Typhoon models depending on your imaging needs. For added flexibility, Typhoon 9200, 9210, and 9400 can be upgraded as imaging needs change. All Typhoon models come with ImageQuant™ TL.



Microarry Slide

A micro-array slide, spotted with cDNA from Micro-array ScoreCard™ control plate and cDNA from Incyte Genomics, Inc. was hybridized with 25 pmol of Cy3-labeled skeletal muscle mRNA and Cy5-labeled liver mRNA. The slide was scanned on Typhoon 9410 at 10 μm pixel size resolution.
 



Two Dimensional 2D- Protein Staining

Two-dimensional 2-D protein gel stained with Deep Purple™ Total Protein Stain. Protein sample consists of HBL100 breast cell line and BT474 breast cell carcinoma. First dimension: Immobiline™ DryStrip pH 3-10 NL, 24cm run on Ettan™ IPGphor IEF System. Second dimension: DALT Gel 12.5 run on Ettan DALTtwelve Large Vertical Electrophoresis System. Scanning: Typhoon 9400 Variable Mode Imager: Excitation, green laser (532 nm); emission 560LP filter, PMT 530 V, 100 μm resolution. The gel image shows the pH 3-8 region, where most proteins are present.



Four-color competitive gel shift assay

Four-color competitive gel shift assay to determine the relative affinities of the Salmonella spp. bacteriophage P22 repressor Mnt (1). In the assay the repressor is allowed to bind four different oligonucloetides labeled with FAM, HEX, TAMRA and ROX respectively at the same time. The intensities for each fluorophore in a lane are related directly to the relative affinity of the repressor protein for the oligonucleotide use

 In-lane sizing of PCR products

In-lane sizing of PCR products. GeneScan -500 ROX size standard (yellow, Applied Biosystems), Cy3-labeled PCR products (green), Alfexpress Cy5 Sizer™ 50-500 (red, GE Healthcare) and fluorescein-labeled PCR products (blue) were resolved in a 12% polyacrylamide gel glass sandwich


References
1. Tsz-Kwong, M. and Stormo, G. D. Nucleic Acids Res. 29, 2471-2478 (2001)

 

SELECTION GUIDE - Typhoon™ Model Capabilities
Typhoon modelStorage phosphor
auto-radiography
ChemiluminescenceDirect red-excited
fluorescence
Direct green-excited
fluorescence
Direct blue-excited fluorescenceMicroarray imaging
capability
     457 nm488 nm 
9200YYYY---
9210YYYY--Y
TrioYYYY-Y-
Trio+YYYY-YY
9400YYYYYY-
9410YYYYYYY


TECHNICAL SPECIFICATIONS FOR THE TYPHOON 9410
Scan area 35 × 43 cm 
Sensitivity (limit of detection) Storage Phosphor: 14C (1 h exposure, 200 and 100 μm only): < 2 dpm/mm2; 32P: 5-10-fold lower than 14C
488 nm excited fluorescence:  100 amol FAM end-labeled DNA primer in 12% polyacrylamide gel sandwich, 0.4 mm thick
532 nm excited fluorescence:  200 amol HEX, TMR, ROX, and 400 amol FAM end-labeled DNA primer in 12% polyacrylamide gel sandwich, 0.4 mm thick
633 nm excited fluorescence:  200 amol Cy5 end-labeled DNA primer in 0.4 mm thick, 12% polyacrylamide gel with TBE buffer.
 
Pixel size 1000, 500, 200, 100, 50, 25, and 10 μm, selectable. 
Spatial resolution Auto-radiography: 2 line pairs/mm for lines drawn with 14C ink.
Blue-excited fluorescence: 10 line pairs/mm
Green-excited fluorescence: 10 line pairs/mm
Red-excited fluorescence: 10 line pairs/mm 
Uniformity ± 5% over entire scan area. 
Pixel accuracy ± 0.15% 
Data format 16-bit (65 536 levels), TIFF 
Linear dynamic range and linearity Five orders of magnitude (100 000:1) with less than 7.5% relative standard deviation for entire dynamic range. 
Red light source Type: 10 mW Helium-Neon laser Estimated average lifetime: ~ 10 000 h Wavelength: 632.8 nm 
Green light source Type: 20 mW solid-state doubled frequency SYAG laser  Estimated average lifetime: ~ 10 000 h Wavelength: 532 nm 
Blue light source Type: 30 mW all blue lines Argon ion laser  Estimated average lifetime: ~ 5000 h Wavelength: 488 nm (20 mW) and 457 nm (4 mW) 
External interface 10 Base-T Ethernet using TCP/IP protocol 
Software Scan control software for Windows™ operating system. 
Power requirements 115/230 V (switchable), 50-60 Hz, < 500 W
 
Dimensions
(W × D × H) 
Instrument: 118 × 78 × 48 cm
Blue laser module: 30 × 78 × 48 cm 
Safety certifications UL 3101, CAN/CSA C22.2 No 1010.1, EN 61010-1, EN60825-1, EN 61326, CE Marking (LVD 73/23/EEC EMC 89/336/EEC), CDRH (FDA) Subpart 21 CFR Ch.1-Part 1040. (Please contact your local GE Healthcare office for the latest list of certifications.) 