Rotina 380R tabletop
refrigerated centrifuge

Rotina 380 tabletop
non-refrigerated centrifuge
The fully developed up- to-date N control panel
meets the requirements of the users and is
extremely easy to operate.
Entry of the parameters is fast, precise and
convenient with selector keys on the
water- protected foil keypad.
The large display is well readable. During
centrifugation the actual values of the
parameters are indicated.
The parameters remain in the memory even after the
centrifuge has been switched off.

 has been
making cutting edge centrifuges longer than any of them. GMI
carries Hettich centrifuges brand new in the box as our exclusive
line for one simple reason...if you are buying new, Hettich is the
best. IT IS the Mercedes of the centrifuge world. Here's
why;
Tradition
The development of modern laboratory centrifuges is closely
connected with the history of Hettich-Zentrifugen. Hettich's roots
go back to 1904. A few years later, Andreas Hettich, the founder of
the company, built the first centrifuges for medical applications.
Ever since, Hettich has been defining the state of the art by
further improving the technology and integrating new ideas. Today,
Hettich's guiding principle is "innovation by tradition".
Innovation
Since the company was founded more than 160 patents and copyrights
for design have been granted to it. Without exception they relate to
centrifuges and centrifuging techniques.
In cytology, in particular, Hettich developed equipment that pointed
the way ahead. In the field of laboratory automation the application
for a patent on a robotic centrifuge presents a recent example of
the company's innovative force.
The Hettich list of applied and issued
patents, therefore, reads like a presentation of the development of
modern centrifuge technology.
Construction and Design
The exchange of ideas with users in medicine, chemistry, industry
and research generates
synergies. Using latest CAD technology Hettich's designing engineers
develop them into products that meet all demands of today's
laboratories. In the factory, finally, they are realized in
centrifuges and accessories that are unmistakably Hettich and prove
their worth not only by functionality, but also practical and
attractive design.
Quality
Hettich manufactures top quality centrifuges. All stages from design
to end product are continually subjected to strictest controls.
Hettich centrifuges meet the requirements of all relevant national
and international standards and verifies this by corresponding
conformity marks. The ISO 9001 certificate accredited to the entire
company proves the extreme care and responsibility Hettich puts into
the manufacture of centrifuges and their accessories.
Service
After the purchase of a centrifuge Hettich and
your local representative is still at your service.
You can rely on excellent post sales support.
We guarantee it!
Buying Hettich represents zero risk. Since Hettich has been in
business for around 100 years you don't have to worry about service
this year, next year, or even in ten years.
Environmental Care
Centrifuges must not only be safe to operate, their manufacture must
also be in compliance with latest ecological findings and pollution
control measures. However, Hettich goes beyond that. Long before the
corresponding law came into force, Hettich, for example, used the
environmentally friendly cooling agent R 404 a on its refrigerated
centrifuges. In addition, all other materials are carefully selected
under the aspects reusability or non-polluting disposability.

Rotor Selection and Adapter / Carrier / Insert
information:
Because this product has a large rotor 'library' and since there are numerous adapters for many different tubes for
these rotors please provide
your specific requirements at time of requesting quote, it is helpful
to provide the physical diameter of the tube and its height measured in
millimeters. We will be delighed to email to you the product brochure which has
comprehensive detail on this centrifuge. To receive it you must fill
out the web form at
our Contact
Page. Alternately, call your sales rep at 800-745-2710
|
|
|
|
Hettich Rotina 380 and Hettich Rotina 38R
refrigerated tabletop centrifuge
The high-performance benchtop
centrifuges ROTINA 38 and ROTINA 380 R impress by state- of- the- art
technology, large capacity, extremely easy handling and
exceptionally smooth and quiet running. Accommodating a multitude of
tubes used in today´s laboratory routine the ROTINA 380 type of
centrifuges enable a wide range of applications. Developed for high
efficiency whisper quiet operation, the
ROTINA 380/380 R are mainly employed in diagnostics, cell culture,
genetics research and microbiology.

$ Ordering Information
Ready to buy, obtain a quotation,
or learn more about this instrument?
Please
click here
& fill out our contact page
or contact our knowledgeable sales force at
763-712-8717 / 800-745-2710 for more information.

Performance:

RCF of up to 3,832 in
this swing-out rotor, max. speed 4,600 rpm
and a vast array of adapters are available for most tubes
Rotor model is 1724

How about this nice Swing-out rotor. RCF of up to
3,095 in
this swing-out rotor, max. speed 4,000 rpm!
Rotor
model=1798

This 6 x 50ml (round
bottom tube) rotor spins up to 11,000 rpm and up to 16,504 x g.
Rotor model=1792

This microcentrifuge rotor is a 30 place
wonder. Up to 15,000 rpm and up to 24,400 x g
Model=1789

Model 1713
microplate rotor for 2 to 4 plates
NEW rotor Model 1797
for 6 x 50ml conical labware ie.,
corning or falcon 50ml tubes. Extreme performance at 14,000 rpm and
up to 22,789 x g
Operation and Additional Features:
Entry of
parameters can be carried out fast and conveniently via the
water-proof foil-keypad. Just a few keys are all it takes to program
the centrifuging parameters. The last entered values will be stored.
They remain in the memory even after centrifuge has been switched
off. By pressing the START key the parameters are recalled.
The clearly arranged display is easy to read. During
centrifugation the actual values are digitally displayed.
Programmable small control, 3
complete operation programs can be stored and recalled.
Speed, RPM: Input in increments of 10
Running time t/min: Input in minutes
Relative Centrifugal Force RCF: Input in increments of 1
Run-up/run-down time: Input of acceleration and braking ramps
in levels 1-9 and unbraked
run-down.
Radius r/mm: Input of the radius is required for determining
RPM and RCF.
Short cycle mode
Temperature, T/°C: Input in increments of 1°C within a range
of -20°C to +40°C (ROTINA 38 R).
Pre-cooling program

GMI carries the full line of Hettich centrifuges
for every one of your Zentrifugen / centrifuging applications
EBA 20 / EBA 20S
EBA 21
HAEMATOKRIT
210
MIKRO 22/22R
MIKRO 120
MIKRO
200/200R
MIKRO 220/220R
ROTOFIX 32A
UNIVERSAL 320/320R
ROTINA 380/380R
ROTINA 420/420R
ROTANTA 460/460R
ROTIXA 50S
ROTO SILENTA
630RS
CUSTOM PRODUCTS are available -inquire
|
|
 |

Accessories:
With
just 9 rotors and an extensive range of accessories almost every kind of
centrifuging required in practice can be undertaken.
Adapters are too numerous to list on web, pdf file may be emailed:
1724 swing-out rotor, 4-place, for max. 4 x 100 ml,
5000 rpm max. RCF 4,528
Adapters
are too numerous to list on web. pdf will be sent with your quote
1726, swing-out rotor, 6-place, for max. 6 x 50 ml, max. RCF 2,808
1720, angle rotor for max. 6 x 85 ml, max. RCF 16,233 ROTINA 35 R,
max. RCF 13,416 ROTINA 35
1711, drum rotor, light metal with lid and 6 compartments for 60
microlitre-PCR, 1.5/ 2.0ml tubes,
max. RCF 16,435
ROTINA 35 R, max. RCF 12,075 ROTINA 35
1717, swing-out rotor, 10-place, for max. 10 x 50 ml (Falcon), max.
RCF 4,556
1725, swing-out rotor, 4-place, for 4 microtitration plates, max. RCF
2,147
1794, swing out rotor, 4-place, max. 4 x 250ml max
up to RCF 2,719
1798, swing-out rotor, 4-place, max up to RCF 3,095
This rotor's adapters are described in detail
below with required bucket 
Tables such as this are found for every contingency in the product brochure
which can be emailed
1792, angle rotor, 6-place, 6 x 50ml,
max. RCF 16,504
1789, angle rotor, 30-place 1.5ml/2.0ml
and PCR tubes, max. RCF 24,400 WOW!
1713, swing out rotor, 2-place, max. RCF 1,968
Rotor Selection and Adapter / Carrier / Insert
information:
Because this product has a large rotor 'library' and since there are numerous adapters for many different tubes for
these rotors please provide
your specific requirements at time of requesting quote, it is helpful
to provide the physical diameter of the tube and its height measured in
millimeters. We will be delighed to email to you the product brochure which has
comprehensive detail on this centrifuge. To receive it you must fill
out the web form at
our Contact
Page. Alternately, call your sales rep at 800-745-2710
Technical
Physical Data
| Consumption: |
ROTINA 380: |
880 VA |
| |
ROTINA 380R: |
1300 VA |
| H x W x D in mm: |
ROTINA 380: |
379 x 468 x 563 |
| |
ROTINA 380R: |
379 x 468 x
563 |
| Weight: |
ROTINA 380: |
47 kg |
| |
ROTINA 380R: |
73 kg |
| Max Capacity: |
4 x
250 ml |
|
| Max RPM/RCF: |
15,000/24,400 Fixed Angle |
|
 |