Global Medical Instrumentation, Inc.









Hettich ROTINA 35 Tabletop Centrifuge

 


Rotina 35R tabletop refrigerated centrifuge


Rotina 35 tabletop non-refrigerated centrifuge

Unique Features

bullet Automatic lid locking, auto lid lift
bullet Frequency-controlled induction drive
bullet High speed stability
bullet 3 complete running programs can be stored and recalled (however XM radio is not available in this model yet)
bullet Automatic rotor recognition
bullet Smooth and QUIET running
bullet Lid with see-through glass
bullet Temperature control in refrigerated models within a range of -20°C to +40°C
bullet 120 blood collection tubes at max. 4.637
bullet Imbalance switch-off
bullet One year warranty

Remember Hettich from GMI!

bullet Environmentally friendly, first to use non-ozone depleting refrigerant R-404, materials and components carefully selected with reusability or non-polluting disposability criteria in mind
bullet Innovative, features and performance not found elsewhere at the same price
bullet 100 years in the making.  Hettich was 1st in centrifugation at the beginning of this century- Andreas Hettich designed the first centrifuge for medical applications!

has been making cutting edge centrifuges longer than any of them.  GMI carries Hettich centrifuges brand new in the box as our exclusive line for one simple reason...if you are buying new, Hettich is the best.  IT IS the Mercedes of the centrifuge world.  Here's why;

Tradition
The development of modern laboratory centrifuges is closely connected with the history of Hettich-Zentrifugen. Hettich's roots go back to 1904. A few years later, Andreas Hettich, the founder of the company, built the first centrifuges for medical applications. Ever since, Hettich has been defining the state of the art by further improving the technology and integrating new ideas. Today, Hettich's guiding principle is "innovation by tradition".

Innovation
Since the company was founded more than 160 patents and copyrights for design have been granted to it. Without exception they relate to centrifuges and centrifuging techniques.
In cytology, in particular, Hettich developed equipment that pointed the way ahead. In the field of laboratory automation the application for a patent on a robotic centrifuge presents a recent example of the company's innovative force.
The Hettich list of applied and issued patents, therefore, reads like a presentation of the development of modern centrifuge technology.

Construction and Design
The exchange of ideas with users in medicine, chemistry, industry and research generates
synergies. Using latest CAD technology Hettich's designing engineers develop them into products that meet all demands of today's laboratories. In the factory, finally, they are realized in centrifuges and accessories that are unmistakably Hettich and prove their worth not only by functionality, but also practical and attractive design.

Quality
Hettich manufactures top quality centrifuges. All stages from design to end product are continually subjected to strictest controls. Hettich centrifuges meet the requirements of all relevant national and international standards and verifies this by corresponding conformity marks. The ISO 9001 certificate accredited to the entire company proves the extreme care and responsibility Hettich puts into the manufacture of centrifuges and their accessories.

Service
After the purchase of a centrifuge Hettich and your local representative is still at your service. You can rely on excellent post sales support.

We guarantee it! 

Buying Hettich represents zero risk.  Since Hettich has been in business for around 100 years you don't have to worry about service this year,  next year, or even in ten years. 

Environmental Care
Centrifuges must not only be safe to operate, their manufacture must also be in compliance with latest ecological findings and pollution control measures. However, Hettich goes beyond that. Long before the corresponding law came into force, Hettich, for example, used the environmentally friendly cooling agent R 404 a on its refrigerated centrifuges. In addition, all other materials are carefully selected under the aspects reusability or non-polluting disposability.

 




Hettich Rotina 35 and Hettich Rotina 35R refrigerated tabletop centrifuge

The high-performance bench-top centrifuges ROTINA 35 and ROTINA 35 R impress by state-of-the-art technology, large capacity, extremely easy handling and exceptionally smooth and quiet running. Accommodating a multitude of tubes used in modern laboratory routine the ROTINA 35 type centrifuges enable a wide range of applications. Ideal  when you don't need the tube spinning capacity of the ROTANTA 460.
Developed for professional users these innovative centrifuges are mainly used in the following fields of application: diagnostics, cell culture, genetic research and microbiology. And I can't emphasize enough how quiet Hettich centrifuges are!

Performance:


RCF of up to 4,556 in this swing-out rotor, max. speed 5,000 rpm and a vast array of adapters are available for most tubes

                                    
                                         Rotor model is 1724

 

How about this nice 50ml conical rotor for up to 4,556 x g for 10 tubes!

 

Rotor model=1717

 



This 6 x 50ml (round bottom tube) rotor spins up to 11,000 rpm and up to 16,504 x g. 

                                                        Rotor model=1792

 


This microcentrifuge rotor is a 30 place wonder.  Up to 15,000 rpm and up to 24,400 x g



Model=1789

 


 

Model 1713 microplate rotor for 2 to 4 plates




Operation and Additional Features:

Entry of parameters can be carried out fast and conveniently via the water-proof foil-keypad. Just a few keys are all it takes to program the centrifuging parameters. The last entered values will be stored. They remain in the memory even after centrifuge has been switched off. By pressing the START key the parameters are recalled.

The clearly arranged display is easy to read. During centrifugation the actual values are digitally displayed.
Programmable small control, 3 complete operation programs can be stored and recalled.
Speed, RPM: Input in increments of 10
Running time t/min: Input in minutes
Relative Centrifugal Force RCF: Input in increments of 1
Run-up/run-down time: Input of acceleration and braking ramps in levels 1-9 and unbraked
run-down.
Radius r/mm: Input of the radius is required for determining RPM and RCF.
Short cycle mode
Temperature, T/°C: Input in increments of 1°C within a range of -20°C to +40°C (ROTINA 35 R).
Pre-cooling program

 

$  Ordering Information

Ready to buy or learn more
about this instrument?


Please
click here & fill out our contact page
or contact our knowledgeable sales force at
763-712-8717 / 800-745-2710 for more information.

GMI carries the full line of Hettich centrifuges for every one of your Zentrifugen / centrifuging applications

  EBA 20
  EBA 21
 
HAEMATOKRIT 210
  MIKRO 22/22R
  MIKRO 120
  MIKRO  200/200R 
  MIKRO 220/220R
  ROTOFIX 32A
  UNIVERSAL 320/320R
  ROTINA 38/38R
  ROTANTA 460/460R
  ROTIXA 50S
 
ROTO SILENTA 630RS
  CUSTOM PRODUCTS Group




Accessories:

With just 9 rotors and an extensive range of accessories almost every kind of centrifuging required in practice can be undertaken.  Adapters are too numerous to list on web, pdf file may be emailed:

1724  swing-out rotor, 4-place, for max. 4 x 100 ml, 5000 rpm max. RCF 4,528
         Adapters are too numerous to list on web. pdf will be sent with your quote
1726, swing-out rotor, 6-place, for max. 6 x 50 ml, max. RCF 2,808
1720, angle rotor for max. 6 x 85 ml, max. RCF 16,233 ROTINA 35 R, max. RCF 13,416 ROTINA 35
1711, drum rotor, light metal with lid and 6 compartments for 60 microlitre-PCR, 1.5/ 2.0ml  tubes,
         max. RCF 16,435
         ROTINA 35 R, max. RCF 12,075 ROTINA 35
1717, swing-out rotor, 10-place, for max. 10 x 50 ml (Falcon), max. RCF 4,556
1725, swing-out rotor, 4-place, for 4 microtitration plates, max. RCF 2,147
1794, swing out rotor, 4-place, max. 4 x 250ml max up to RCF 2,719

This rotor's adapters are described in detail below with required bucket  
                      Tables such as this are found for every contingency in the product brochure which can be emailed

1792, angle rotor, 6-place, 6 x 50ml,  max. RCF 16,504 ROTINA 35 R, max. RCF 13,640 ROTINA 35
1789, angle rotor, 30-place 1.5ml/2.0ml and PCR tubes, max. RCF 24,400  WOW!
1713, swing out rotor, 2-place, max. RCF 1,968

Adapter / Carrier / Insert NOTE:

Since there are numerous adapters for many different tubes for most rotors please provide your specific requirements at time of requesting quote,  it is helpful to provide the physical diameter of the tube and its height measured in millimeters.  We can email or fax to you the product brochure which has comprehensive detail on your centrifuge.  To receive it you must fill out the web form (completely) at
our Contact Page

Technical Physical Data

Consumption: ROTINA 35:  880 VA
  ROTINA 35 R: 1300 VA
H x W x D in mm: ROTINA 35: 380 x 468 x 540
  ROTINA 35 R: 380 x 468 x 695
Weight: ROTINA 35: 43,0 kg
  ROTINA 35 R: 70,0 kg
Order No. 1705, ROTINA 35, w/o rotor
  1710, ROTINA 35 R, w/o rotor

 


 
  Accepting all major credit cards:     At GMI...its instrumental !

  GMI, Inc.
  6511 Bunker Lake Blvd.  
  Ramsey,   Minnesota, 55303   USA
  Tel. 763-712-8717          Fax 763-712-8724 
 
Send electronic mail to
tom@gmi-inc.com

 




Home Page  |  GMI Catalog  |   Search  |  What's New  |  Ordering  |   Contact  |  Service  |  Contents

General Lab Products  |  Analytical Products  |  Clinical Products  |  Biotech Products  |  Medical Instruments


Copyright © 1999 through 2006.  This page and all associated pages (web archived and all other)  (and their HTML) of this website and all content at www.gmi-inc.com are the sole property of Global Medical Instrumentation, Inc. and are protected by GMI copyright protection laws and may not be reproduced in any form nor may any content or any  images be removed without the owner's express written permission. All instruments mentioned on our web site are the trademarks of their respective manufacturer.  GMI, Inc. makes no claims of special affiliation with or special sanctions by the original manufacturers or their respective trademarks. The appearance of those names is not intended to imply that GMI  is an officially authorized dealer or distributor for those manufacturers .   Purchases are subject to GMI Terms and Conditions of Sale found on our Contact and Ordering page.  ***Inventory changes daily, please call for availability and for items not seen or listed.   We look forward to hearing from you!