Rotanta 460 tabletop
refrigerated

Rotanta 460 tabletop
non-refrigerated
Unique Features
 |
Automatic lid locking, auto lid lift |
 |
Frequency-controlled induction drive |
 |
Automatic rotor recognition |
 |
Digital control panel (can store up to 3
to 89 programs with N panel) |
 |
4 x 750
ml at max. 4,779 RCF |
 |
up to 24 microtitre plates / 4 filter
plates at max. 4.235 RCF |
 |
18,038
RCF with a max.
capacity of 6 x 94 ml |
 |
14,025
RCF with a max.
capacity of 6 x 250 ml |
 |
24
microtitre plates / 4 filter plates at
max. 4.235 RCF |
 |
12
microtitre plates / 2 filter plates at
max. 6.446 RCF |
 |
24,400 RCF with a max. capacity of 30
microcentrifuge tubes (1,5 / 2,0 ml) |
 |
Temperature control in refrigerated models within a range of -20°C
to +40°C |
 |
120
blood collection tubes at max. 4.637 |
 |
Imbalance switch-off |
 |
One year warranty |
Choice of 2 Control panels:

Programming the
centrifuges is extremely easy. With the standard N control panel
entry of the parameters is fast and precise with selector keys
on the foil keypad. During centrifugation the actual values of the
parameters are displayed. Three complete running programmes can be
stored and recalled.

Maximum user-friendliness is provided by the extended S control
panel (optional). With little manipulation a multitude of
functions can be programmed via selector keys on the foil keypad and
an adjusting knob. Up to 89 running programmes can be memorized and
recalled by their storing number. Models with the S control panel may
be fitted with an interface for recording the centrifuging parameters
with the data report system HETTINFO.
All centrifuges of the ROTANTA 460 line feature automatic lid locking.
When the rotor has come to a standstill after centrifugation the lid
opens at the touch of a button. With the refrigerated ROTANTA 460
centrifuges temperature is controllable within a range of -20°C to
+40°C, accurate to 1°C
Remember Hettich
from GMI!
 |
Environmentally friendly, first to use
non-ozone depleting refrigerant R-404, materials and components
carefully selected with reusability or non-polluting disposability
criteria in mind |
 |
Innovative, features and performance not found
elsewhere at the same price |
 |
100 years in the making. Hettich
was 1st in centrifugation at the beginning of this century- Andreas Hettich designed the first
centrifuge for medical applications! |

 has been
making cutting edge centrifuges longer than any of them. GMI
carries Hettich centrifuges brand new in the box as our exclusive
line for one simple reason...if you are buying new, Hettich is the
best. IT IS the Mercedes of the centrifuge world. Here's
why;
Tradition
The development of modern laboratory centrifuges is closely
connected with the history of Hettich-Zentrifugen. Hettich's roots
go back to 1904. A few years later, Andreas Hettich, the founder of
the company, built the first centrifuges for medical applications.
Ever since, Hettich has been defining the state of the art by
further improving the technology and integrating new ideas. Today,
Hettich's guiding principle is "innovation by tradition".
Innovation
Since the company was founded more than 160 patents and copyrights
for design have been granted to it. Without exception they relate to
centrifuges and centrifuging techniques.
In cytology, in particular, Hettich developed equipment that pointed
the way ahead. In the field of laboratory automation the application
for a patent on a robotic centrifuge presents a recent example of
the company's innovative force.
The Hettich list of applied and issued
patents, therefore, reads like a presentation of the development of
modern centrifuge technology.
Construction and Design
The exchange of ideas with users in medicine, chemistry, industry
and research generates
synergies. Using latest CAD technology Hettich's designing engineers
develop them into products that meet all demands of today's
laboratories. In the factory, finally, they are realized in
centrifuges and accessories that are unmistakably Hettich and prove
their worth not only by functionality, but also practical and
attractive design.
Quality
Hettich manufactures top quality centrifuges. All stages from design
to end product are continually subjected to strictest controls.
Hettich centrifuges meet the requirements of all relevant national
and international standards and verifies this by corresponding
conformity marks. The ISO 9001 certificate accredited to the entire
company proves the extreme care and responsibility Hettich puts into
the manufacture of centrifuges and their accessories.
Service
After the purchase of a centrifuge Hettich and
your local representative is still at your service.
You can rely on excellent post sales support.
We guarantee it!
Buying Hettich represents zero risk. Since Hettich has been in
business for around 100 years you don't have to worry about service
this year, next year, or even in ten years.
Environmental Care
Centrifuges must not only be safe to operate, their manufacture must
also be in compliance with latest ecological findings and pollution
control measures. However, Hettich goes beyond that. Long before the
corresponding law came into force, Hettich, for example, used the
environmentally friendly cooling agent R 404 a on its refrigerated
centrifuges. In addition, all other materials are carefully selected
under the aspects reusability or non-polluting disposability.
|
|
|
|
Hettich Rotanta 460 centrifuge
Beckman? Sorvall? Hettich has been
making cutting edge centrifuges longer than both of them. GMI
carries Hettich centrifuges brand new in the box as our exclusive
line for one simple reason...if you are buying new, Hettich is the
best. IT IS the Mercedes of the centrifuge world.
For
decades,
ROTANTA centrifuges from Hettich have been distinguished by the
highest quality. They have responded to the fast-paced changes in
laboratory environments with the continuous development of new,
technically outstanding solutions. The ROTANTA 460 models are
carrying on this tradition of quality. Enhanced performance
and an extended range of accessories guarantee fast, trouble-free
operation in daily laboratory use. With a maximum capacity of 3
litres per run, they are proving themselves in clinics and
laboratory centers, as well as in Life
Science R&D departments.
With high throughput, short separating
times, fully developed technology, and a wide range of accessories
the ROTANTA 460 models perfectly meet the requirements of modern
Life Science laboratories. Maximum
6,446 RCF can be generated with a swing-out rotor, 24,400 RCF with
an angle rotor. In swing-out position e.g. up to 120 blood
collection tubes, 240 x 2 ml microlitre tubes, 4 x 750 ml bottles,
24 microtitre plates, 4 deep well plates with filter columns for
RNA/DNA purification can be processed per run. For seperation in
angle position a choice of 3 rotors for max. 6 x 94 ml, 6 x 250 ml,
and 30 x 1.5/2 ml is available. With aerosol-tight (TÜV-tested in
compliance with DIN EN 61010, part 2 - 020) and autoclavable
accessoires (up to 121°C or 134°C) also infectious samples can be
centrifuged safe for operator and environment.
For sample processing in clinical
chemistry, a wide selection of adapters are available to accommodate
the most varied types of tubes. Biotechnology, molecular biology and
the pharmaceutical industry value the ROTANTA 460 especially for its
autoclavable and aerosol-tight accessories.
These versatile benchtop centrifuges feature many
rotors including a microtitre plate
rotor with a RCF of 6,446 for purifying DNA / RNA.
Is it possible
that this one centrifuge can replace your floor model high speed
centrifuge AND your tabletop large capacity centrifuge? Read on...

Consider:

Buy a 4 x 750ml
rotor (model 5624) for large volumes and all of your tube and bottle
spins such as 15 and 50ml conical disposable labware at 4779 x g and
4600
Rotor model 5624 rpm! Adapters exist for 12mm, 17mm, 24mm, 34mm, 40mm, 44mm, and
65mm diameter tubes with volume range of 5ml, 6ml, 7ml, 15ml, 25ml,
50ml, 100ml, 250ml, 450ml, 580ml, and 750ml. All standard
blood collection tubes / vacutainers are accommodated as well as
15ml, 50ml, 175ml, 225ml, 250ml, and 500ml conical labware! Blood
bags are no problem either.

Buy a 30 place
(model 4489) 1.5ml (and 0.2, 0.4, & 0.5 and 0.8ml) microcentrifuge
tube rotor for your Eppendorf tube spins - 15,000 rpm and 24,400 x
g. WOW, you mean I don't need a separate refrigerated
Model 4489 microcentrifuge? !
Buy a 6 place
50ml (model 5615) oak ridge tube rotor and spin your tubes at 11,500
rpm and up to 17,299 x g! Wow, you mean I don't have to run
off to
Model 5615
find my JA 20 or SS 34 rotors? Nope, not with the Rotanta 460 centrifuge!
Buy a 6 x 250ml
(model 5645) rotor for spinning down your bacterial cultures.
You can spin 9500 rpm at up to 14,025 x g!
Microplates? No
problem, you can spin 2, 4, 6, 8 10 or even 12 microtiter plates at
up to 6446 x g. You may even spin deep well plates
$ Call
for a competitive quotation
at
763-712-8717 or at our Contact
Page

GMI carries the full line of Hettich centrifuges
for every one of your Zentrifugen / centrifuging applications
HAEMATOKRIT 210
EBA 20
EBA 21
MIKRO 120
MIKRO
200
MIKRO 22
ROTOFIX 32
UNIVERSAL 32
UNIVERSAL 320
ROTINA 35
ROTINA 38
ROTANTA 460
ROTIXA 50 S
ROTO SILENTA
630 RS
CUSTOM PRODUCTS Group
|
|
 |

Accessories:
PN
Description
5624 swing-out rotor, 4-place, for max. 4 x 750 ml, max. RCF
4,779, max. RPM 4,600 min-1
This rotor's adapters are described in detail below with required bucket
(5620 shown at left)

Tables such as this
are found for every contingency in the product brochure which can be emailed
4446, swing-out rotor, 6-place, for max. 6 x 250 ml, max.
RCF 3,631, max. RPM 4,000 min-1
4620, swing-out rotor, 2-place, for max. 12 x microtitre
plates, max. RCF 5,858 with max. RPM 5,900
non-refrigerated, max. RCF 6,446 with max. RPM 6,200 min-1
refrigerated, aerosol-tight
5615, angle rotor, 6-place, for max. 6 x 94 ml, max. RCF
18,038, max. RPM 11,500 min-1, aerosol-tight
5645, angle rotor, 6-place, for max. 6 x 250 ml, max. RCF
11,228 with max. RPM 8,500 min-1
non-refrigerated, max. RCF
14,025 wirh max. RPM 9,500 min-1 refrigerated, aerosol-tight
4489, angle rotor, 30-place, for max. 30 x 1.5/2 ml, max.
RCF 24,400,
max. RPM 15,000 min-1, aerosol-tight
5616, disc rotor, 6-place, for max. 6 x 50 ml Schlenk
tubes, max. RCF 805, max. RPM 2,000 min-1
4474, swing-out rotor, 4-place, for max. 4 x 100 mlo ASIM
tubes, max. RCF 984, max. RPM 2,000 min-1
5694, swing-out rotor, 4-place, n = 4,000 min-1
4619, disc rotor, 6-place, for chrome bath tubes, n = 2,000
min-1, RCF 917

We also carry carts for your
centrifuge!
Inquire for sizes and pricing
Adapter / Carrier / Insert NOTE:
Since there are numerous adapters for many different tubes for most rotors please provide
your specific requirements at time of requesting quote, it is helpful
to provide the physical diameter of the tube and its height measured in
millimeters. We can email or fax to you the product brochure which has
comprehensive detail on your centrifuge. To receive it you must fill
out the web form (completely) at
our Contact
Page
Technical
Physical Data
| Power
supply*: |
ROTANTA
460/460 S |
208-240 V /
50-60 Hz 1 ~ |
| |
with Cat. No.:
5600-01/5601-01 |
110 - 127 V /
50-60 Hz 1 ~ |
| |
ROTANTA 460 R/460 RS |
220-240 V / 50 Hz 1 ~ |
| |
with Cat. No.:
5605-01/5606-01 |
110 - 127 V / 60
Hz 1 ~ |
| Consumption: |
ROTANTA 460 / 460S |
1.5 kVA |
| |
fwith Cat. No..
5600-01/5601-01 |
1.3 kVA |
| |
ROTANTA 460 R / 460 RS |
1.9 kVA |
| |
with Cat. No..:
5605-01/5606-01 |
2.0 kVA |
| H x W x D in mm: |
ROTANTA 460 / 460S |
453 x 554 x 707
|
| |
ROTANTA 460 R / 460 RS |
453 x 770 x 707 |
| Weight: |
ROTANTA 460 / 460S |
89.5 kg |
| |
ROTANTA 460 R / 460 RS |
125 kg |
| Cat. No: |
|
|
| 5600 |
ROTANTA 460 |
without Rotor |
| 5600-01 |
ROTANTA 460 |
without Rotor |
| 5601 |
ROTANTA 460 S |
without Rotor |
| 5601-01 |
ROTANTA 460 S |
without Rotor |
| 5605 |
ROTANTA 460 R |
without Rotor |
| 5605-01 |
ROTANTA 460 R |
without Rotor |
| 5606 |
ROTANTA 460 RS |
without Rotor |
| 5606-01 |
ROTANTA 460 RS |
without Rotor |
 |