Global Medical Instrumentation, Inc.
 
 
 
 
 









ABI Prism 3730xl DNA Analyzer

 


ABI Prism 3730xl DNA Analyzer

The 96-capillary 3730xl DNA Analyzer is the Gold Standard for high throughput genetic analysis. Use this for DNA fragment analysis applications such as microsatellites, AFLP, SNP analysis, mutation detection and traditional DNA sequencing.
Very l
ow cost per sample
.

  • In-capillary detection by dual-side illumination
  • Backside-thinned CCD for maximum optical sensitivity
  • Multiple Filter Sets: Z, E, G5, G5-RCT, Any4Dyeset, Any5Dyeset
  • Actively temperature-controlled oven and detection cell heater
  • Automated polymer replenishment pump for increased throughput
  • Data Collection and Analysis Software
  • Automated basecalling, genotyping, and quality value assignment
  • Integrated auto-sampler and sample plate stacker
  • Automated polymer replenishment pump for increased throughput
  • On-board reagents for up to 48-hours of unattended operation

Full Product Review

Any scientist that has used the traditional Sanger DNA sequencing method is aware that the process is tedious, time consuming and messy due to the involvement of radioisotopes and harsh chemicals. The ABI 3730xl DNA Analyzer offers an alternative in the form of a fully automated system. The protocol involves a PCR reaction using a very robust Mastermix (BigDye from Applied Biosystems), reaction purification and plate loading on the 3730xl. The instrument does all subsequent analysis, requiring only operator loading of 96-well plates.

Several advantages were noted for the ABI 3730xl system. First, the accompanying software package is intuitive and comprehensive. Also, up to sixteen 96-well plates can be loaded on the stacker for high-throughput automated processing. Although attention is required to ensure adequate buffer, polymer and waste levels are maintained, this instrument was extremely hands-free. The actual operation of the instrument, even data analysis, was very simple. The only precursory step to the sequencing reaction is a spectral calibration that ensures all capillaries are functioning properly and the signal is strong enough for detection.

The 3730xl uses the BigDye Terminator reagent that is the most stable and most consistent in the market today. This chemistry is also the most prevalent, which has lead to many laboratories to tinker with it so that there is a wealth of knowledge about what can and cannot be done with it. Thanks to the extensive use of the BigDye Terminator reagent by many core labs, scientists have been able to dilute this dye significantly. Although this needs to be validated on a per-lab case, the savings that can be made are very significant.

While reagents like the BigDye Terminator can be relatively cheap when diluted, there are other components of the instrument that are expensive. A 96-capillary array can be used for about one hundred runs or so and it can be pushed for more with concomitant decrease in sequence read quality. Each one of these capillaries is not cheap. In addition, the polymer that is used to run the instrument gets used up very fast, and that too is not cheap.

The footprint of the 3730xl is only 100 cm x 73 cm x 89 cm (WxDxH). While not small, it occupies a relatively small area compared to the amount of data it generates. It can be placed on a table top or the side of a bench just like you would an average sized table-top centrifuge (at 180 kilograms (almost 400 pounds), the 3730xl is not a machine that you want to move around). Also, the 3730xl generates a considerable amount of heat, so it is advisable to install vents and keep the air conditioning running, even during the times when the machines is running multiples plates through the night. Failure to do so can adversely affect the quality of the sequencing reads. The instrument needed to be cleaned regularly to sustain top performance, thus maintenance can be time consuming. Maintaining the system required that the polymer blocks were removed and rinsed with water, frequently posing issues when connections were not properly reassembled. In addition, the polymer was not very stable at room temperature when the instrument was not used at full capacity, thus requiring replacement. For this reason, even short breaks in instrument usage required a water rinse to clean residual polymer. All of the maintenance steps were more labor intensive than intellectually challenging, since the software walks you through the process step by step and the user manual was a great resource, as well.  With a capacity of about 1 million base pairs per day, it not only provides an incredible capacity, but also flexibility.

 

 






ABI Prism 3730xl DNA Analyzer

The ABI 3730xl DNA Analyzer, a 96-capillary sequencer, is the most robust sequencer on the market. With its production capacity of more than one million nucleotides per day, it is ideal for executing mega-large sequencing projects. It was brought to the market in 2002 by Applied Biosystems

The 3730xl Analyzer provides your laboratory
and production facility with very fast high quality genetic analysis and throughput. The high signal-to-noise ratio ensures you get high-quality data -- even when you use low-concentration samples and reagents. Labor-saving automation features minimize hands-on time and enable you to analyze more data more efficiently. With the 3730xl DNA Analyzer, you get the highest-quality data from a wide array of applications. Load and run up to 8 x 96 templates in continuous automated operation with less than 1 hour of instrument attendance/labor per 24 hour period.  In addition to being ideal for high-throughput sequencing, the analyzer's optimized application assays, instrument, and analysis software also provide a complete solution for genotyping and resequencing.

Specifications:

bullet

Argon-ion multi-line, single mode laser: primary excitation lines 488 and 514.5 nm

bullet

Houses 16 sample plates at any time

bullet

36cm or 50cm capillaries

bullet

XLRseq:
768 samples per day (690 Kbases) 50cm, 900 QV20 bases/3 hours

bullet

LongSeq:
1152 samples/day (980 Kbases)
50cm, 850 QV20 bases/2 hours

bullet

StdSeq:
2304 samples/day (1550 Kbases)
36cm, 700 QV20 bases/1 hour

bullet

RapidSeq:
3840 samples per day (2100 Kbases)
36cm, 550 QV20 bases/36 min

 

In addition to its 96 capillaries, the ABI 3730xl is equipped with an electrophoresis system, a laser, and a CCD camera. The capillaries, having a diameter of approximately 250 um, are filled with a polymer that acts as a molecular sieve. The DNA molecules are introduced into one end of the capillaries by electroinjection, and migrate through these capillaries under the attraction of high voltage (8500 V) at which point the molecules are separated according to their lengths. Close to the anode, a laser passes through each capillary and excites the fluorescent molecules incorporated onto the DNA during the reaction sequence. A CCD camera collects the information emitted by the fluorescent molecules as they pass in front of the laser. As each one of the four nucleic bases (A, C, G, and T) associates with a specific fluorochrome, the system distinguishes one base from another according to their respective wavelengths emitted. Subsequent data is analyzed, "base called," and filed when electrophoresis is complete.

 

This item is in stock as of 9/2/07
You can reserve/order this instrument
by calling 763-712-8717 or by
completing the form on the
Ordering Page.

 
 

 


 
  Accepting all major credit cards:      At GMI...its instrumental !

  GMI, Inc.
  6511 Bunker Lake Blvd.  
  Ramsey,   Minnesota, 55303   USA
  Tel. 763-712-8717          Fax 763-712-8724 
 
Send electronic mail to richard@gmi-inc.com

  


Copyright © 1998 - 2006  This page and all associated pages and all archived web HTML (and their HTML) of this website and all content at www.gmi-inc.com are the sole property of Global Medical Instrumentation, Inc. and are protected by GMI copyright protection laws and may not be reproduced in any form nor may any content or any  images be removed without the owner's express written permission. All instruments mentioned on our web site are the trademarks of their respective manufacturer.  GMI, Inc. makes no claims of special affiliation with or special sanctions by the original manufacturers or their respective trademarks. The appearance of those names is not intended to imply that GMI  is an officially authorized dealer or distributor for those manufacturers .   Purchases are subject to GMI Terms and Conditions of Sale found on our Contact and Ordering page.  ***Inventory changes daily, please call for availability and for items not seen or listed.   We look forward to hearing from you!