You are here: GMI Biotech Analytical Spectroscopy Liquid Scintillation Beckman Scintillation Instruments Beckman LS 6000 Scintillation Counter

New and Used Lab Equipment - GMI Inc

Loading
Analytical arrow Spectroscopy arrow Liquid Scintillation arrow Beckman Scintillation Instruments arrow Beckman LS 6000 Scintillation Counter (WS-BECKLS6)

Beckman LS 6000 Scintillation Counter

  • 32,768 Channels Multichannel Analyzer
  • Advanced Photomultiplier Design
  • Interlocking Lead Shielding
  • Windowing User Interface
  • User-Selectable Output Format

Shop for parts
Hard to find Part? Request a quote.
A parts specialist will find it for you!

... Full Description >>>


Complete Product Description

The Beckman LS 6000 Liquid Scintillation Counter offers flexibility that is unparalleled in a single high performance system. The LS 6000 can function independently of an external computer.

The LS 6000 has a 32,768 channel multichannel analyzer which gives you an eight-fold improvement in effective resolution (0.06 keV per channel) over that of conventional liquid scintillation counters (0.5 keV per channel). This provides the basis for: DPM results without quench curves A more precise quench monitor Superior results for multi-label studies Automatic color detection and correction.

Program selection is accomplished through the use of command cards.

Counting single racks without command card (under interrupt in the Multi Task menu), single photon counting, and dual label studies. Entering user programs involves selection of isotopes to set spectrometer windows rather that actual window energies. Thus, if you wish to count tritium in channel 1 you would select 3H for isotope one (actually this is the default). If you wish to manually set the window you may do so by entering Manual in this field. Please refer the the manual for detailed instructions. It is important to note that if are doing a dual labeling study you should choose Isotope 1 as the lower energy isotope and Isotope 2 as the higher energy isotope. The lower limit for Isotope 2 is set the same as the upper limit for Isotope 1. Don't define multiple isotopes in singlely labeled studies as it will result in lowered counts.

Other Products in this Category

Beckman LS 6500 Scintillation Counter
Beckman LS 6500  Scintillation Counter
Get a Quick Quote
Packard Tri-Carb Liquid Scintillation Counter
Packard Tri-Carb Liquid Scintillation Counter
Get a Quick Quote
Wallac 1450 MicroBeta TriLux Liquid Scintillation Counter & Luminometer
Wallac 1450 MicroBeta TriLux Liquid Scintillation Counter & Luminometer
Get a Quick Quote
Packard RIASTAR Scintillation Counter
Packard RIASTAR Scintillation Counter
Get a Quick Quote