Beckman Coulter IMMAGE Immunochemistry System
Beckman Coulter IMMAGE Immunochemistry System
| Product Description |
The Beckman Coulter IMMAGE Immunochemistry System utilizes four high-performing and tested detection technologies to deliver accurate testing for specific proteins and therapeutic drugs.
The IMMAGE Immunochemistry systems boast of a design tailored for productivity. Several functions can be carried out simultaneously in each five-second system cycle. These procedures include calibration, sample processing analysis, cuvette washing as well as sample and reagent pipetting.
The IMMAGE Immunochemistry systems boast of a design tailored for productivity. Several functions can be carried out simultaneously in each five-second system cycle. These procedures include calibration, sample processing analysis, cuvette washing as well as sample and reagent pipetting.
Take advantage of the Near-infrared Particle Immunoassay System (NIPIA) offered by the IMMAGE system. Increases analytical sensitivity nearly a thousand-fold to address lower molecular weight analytes, such as digoxin, ferritin and IgE with the IMMAGE Immunochemistry system’s unique feature. The Beckman IMMAGE model streamlines laboratory operation and increases throughput.
Call us today to learn more about the Beckman Coulter IMMAGE Immunochemistry System!
|
Beckman IMMAGE |
|
|
Technique |
Rate nephelometry |
|
Testing Mode |
Kinetic |
|
Throughput |
Up to 180 tests/hr |
|
Photodetector |
Silicon photodiode |
|
CLIA Complexity |
Moderate |
|
Physical |
|
|
Power/Energy (VAC) |
115/230 Rate near-infrared particle immunoassay and rate turbidimetry. |
|
Hz |
50/60 |
|
Printer (External Beam) |
8.5 x 11" ink jet |
|
Illumination Source |
Laser : LED |
|
Others |
Keyboard, bar code, control panel (patient data) |
|
Additional (Alarms, high/low) |
LIS interface, touchscreen, mouse |
|
Display |
|
|
Type |
Color VGA monitor |
|
Interface Protocol (Report) |
ASTM, host query, host communication |
|
Dimensions (HXWXD) |
76.2 x 110.5 x 64.8 (cm) |
|
Weight |
123 kg (270 lb) |
|
Reagent Volume, Assay |
21 µL antiserum, 300 µL buffer, |
|
Data Input |
Auto Functions |
|
Operational Mode |
Random access - for details please see comments.Random access Also anti-DNase B and IgE (WIP), digoxin and ferritin (IMMAGE only), alpha 1-microglobulin, and Lp(a). |
|
Additional (Alarms, high/low) |
Same as 360, plus bar-code reader 4 |
|
Detect Angle |
90 deg: Near 0 Also normalization of optics; reagent tracking, including calibration, tests remaining, and expiration date; and switch to fresh reagent. |
|
Operating Temperature |
15-32 deg C (59-89.6 deg F) |
|
Substitution (Slide Carriers) |
Yes |
|
Wavelength, nm |
670 : 940 |
|
Tests (Aperture) |
|
|
Alpha 1-acid glyco |
Yes |
|
Alpha 1-antitryp |
Yes |
|
Alpha 2-macroglob |
Yes |
|
Prealbumin |
Yes |
|
Albumin (BASIC/TIME, min) |
Yes |
|
Antistreptolysin o |
Yes |
|
Antithrombin iii |
Yes |
|
Apolipoprotein a1 |
Yes |
|
Apolipoprotein b |
Yes |
|
C3 complement |
Yes |
|
C4 complement |
Yes |
|
Ceruloplasmin |
Yes |
|
C-reactive protein (Also hsCRP) |
|
|
Haptoglobin |
Yes |
|
Iga (SPECIAL/TIME, min) |
Serum, CSF |
|
Igg (SPECIAL/TIME, min) |
Serum, CSF, urine |
|
Igm (SPECIAL/TIME, min) |
Serum, CSF |
|
Kappa light chain |
Serum, CSF |
|
Lambda light chain |
Serum, CSF |
|
Properdin factor b |
Yes |
|
Rheumatoid factor |
Yes |
|
Transferrin |
Yes (also in urine) |
|
Additional (Alarms, high/low) |
Microalbumin in urine |
|
Pharmaceuticals |
Yes |
|
Carbamazepine |
Yes |
|
Gentamicin (Drug Assay/Time, min) |
Yes |
|
Phenobarbital |
Yes |
|
Phenytoin (Drug Assay/Time, min) |
Yes |
|
Valproic acid |
Yes |
|
Theophylline (Drug Assay/Time, min) |
Yes |
|
Tobramycin |
Yes 3 |
|
Other Attributes |
Single-point calibration |