Beckman Coulter MAXM Hematology Flow Cytometry Systems
Beckman Coulter MAXM Hematology Flow Cytometry Systems
| Product Description |
The Beckman Coulter MAXM is a reliable, easy-to-use, and compact hematology analyzer that is excellent for mid-size volume handling. The Beckman Coulter hematology analyzer has an optional autoloader which allows walkaway operation. Equipped with the MAXM analyzer, the user can load 25 bar-coded samples and then just walk away.
The Beckman MAXM Hematology Flow Cytometer allows the user to measure about 50-300 CBCs per day, and has a throughput capacity of up to 75 tests per hour. The Beckman cytometer works using a three dimensional VCS technology, and provides a semi-automated reticulocyte analysis. Most importantly, the analyzer system requires no routine daily maintenance.
Other useful features of the Beckman Coulter MAXM Cytometer include positive patient identification, automatic calibration, auto-probe wipe, single-operator interface, and continuous computer monitoring of system performance.
Call us today to learn more about the Beckman Coulter MAXM Cytometer!
| Beckman Coulter MAXM | |
| Full Automation | Yes |
| Counts/Dilution (Aperture) | 3 |
| Sample Volume, mL (Detection process, HR) | 185 primary mode, 50 predilute mode, 125 secondary mode |
| Power Required | 105-125/220-240 VAC |
| Dimensions (HxWxD) (Display) | 33 cm x 96.5 cm x 40.6 cm (13 in. x 38 in. x 16 in.) analyzer; 48.3 cm x 96.5 cm x 53.3 cm (19 in. x 38 in. x 21 in.) diluter |
| Weight | 134 kg (295 lb) |
| Technique | Volumetric impedance, high-frequency conductivity, light scatter |
| QC Programs | Automatic: bar-coded controls, Coulter IQAP, 15 files, 100lines with trend analysis, 20 files with reticulocytes |
| Visual Output | Color CRT, graphics printer, optional ticket printer |
| Modify-able Threshold | Set for each parameter |
| Testing Pace | 75 |
| Interface Protocol(Report Display) | Yes; optional bi- directional interface |
| Autosampling | Available as field upgrade option |
| Number of Staining Posts | 2 |
| Size(s), mm (Aperture) | 50100 VCS flow cell |
| Calibration | Automatic using S-CAL |
| Patient ID | Bar code |
| Dilution | Automatic |
| Histogram Display | Yes |
| Closed-tube Sampling | Yes |
| Cycle Duration, sec | 45 |
| Start-UP Time, min | <5 |
| Storage Capacity | 1,000 reports with scatter plots and histograms (5,000 reports with reticulocyte upgrade) |
| Warning Signals (Revolution) | Audible and visualAudio, color status and stop alarm for sample, QC and system errors, aspiration and clog errors |
| Coincidence Correct | Yes |
| Tests | WBC, RBC, Hgb, Hct, MCV, MCH, MCHC, RDW, Plt, MPV, L#, L%, M#, M%, N#, N%, E#, E%, B#, B%; Retic%, Retic# with upgrade kit |