Awareness Technologies Stat Fax 303 Plus Microstrip Reader
Awareness Technologies Stat Fax 303 Plus Microstrip Reader
| Product Description |
The Awareness Technology Stat Fax 303 Plus Microstrip Reader is a compact, fully automatic reading unit with biochromatic optics designed for in-vitro diagnostic use. The instrument also calculates the results of endpoint colorimetric assays.
The Stat Fax 303 Plus reads monochromatically or bichromatically, and accepts many single column microstrips up to 12 wells in length, as well as break-apart wells with either flat- or round bottoms. After positioning the carrier to the desired row, the reader automatically positions the strips, reads absorbances, calculates concentrations, and prints results. The built-in thermal graphics printer also allows the Awareness Technology microstrip reader to plot standard curves.
Additionally, the Stat Fax 303 Plus instrument offers pre-programmed modes for performing the most commonly used calculations, multiple convenience features, and user programmable memory to further facilitate testing. Each mode is self-prompting, minimizing error and simplifying operation for the user.
The Stat Fax 303 Plus reader is designed for convenience, and includes automatic blanking options, as well as the ability to indicate the locations of positive and negative controls. The user can enter control acceptance criteria for automatic comparisons, and edit out discrepant duplicates with automatic reread and recalculation. The microplate reader is also equipped with a user-programmable memory that allows the operator to store test protocols, recall tests by number, and delete unwanted tests from a user-generated test menu.
Call us today to learn more about the Awareness Technology Stat Fax 303 Plus Microstrip Reader!
| PHOTOMETRIC | |
| Linear Measurement Range | 000 to 30 Absorbance Units (A) |
| Photometric Accuracy | ± (1% of the reading + 001 A) from 0 to 15A ± (2% of the reading + 001 A) from 15 to 30A |
| Stability | Drift of no more than 0005A in 8 hours |
| Warm up Time | 45 seconds, built-in |
| Light Source | Tungsten Lamp |
| Standard Wavelengths | Standard: 405, 450, 492, 630nm Six Filter UV: 405, 450, 492, 630, 545, and 340 nm Six Filter VIS: 405, 450, 492, 630, 600, and 545 nm |
| Type of Filter | 3-cavity hard coat interference filter, 10nm half band pass typical |
| Vessel | Single, double, or break apart strips, up to 12 wells long, 3 strip loading capacity |
| ELECTRONIC & SOFTWARE | |
| Speed | Reads, calculates and prints results for up to 12 wells in about 30 seconds |
| Display | LCD, 16” characters, 5x7 dot matrix |
| Internal Printer | Thermal, dot matrix, 20 characters per line |
| Keyboard | 16-key, membrane switch, 4X4 |
| Calculation Modes | Single point calibration, Multi-point calibration with regression or point-to-point curve fit, cutoff, cutoff control, % Absorbance Multi-Point, Uptake |
| Serial Port | Output only, 2400 Baud, 1 start bit, 8 data, 1 stop, no parity, no handshake |
| Power Source | Switch selectable power supply (115V or 230V indicated) Voltage Source 110-120/220-240 VAC from 50 to 60 Hz, CAT II Power consumption is less than 50 Watts Fuse: two 1/2A, T rating, 250V, 3AG type fuse |
| PHYSICAL | |
| Enclosure | ABS Plastic cover with metal base |
| Dimensions | Approx 9”x 12” x 3” (23 x 30 x 8 cm) |
| Weight | 13 lbs (59 Kg) |